All of the staff that work at Backyard Plus are outstanding but I must give Paul B. a special shout out. He is so patient and understanding when dealing with two hot tub owners trying to repair a 2007 Solana tub (replaced everything inside the service panel of the hot tub). His customer service skills are the best I have ever had the opportunity to experience firsthand as a DIY'er I have dealt with many. I truly cannot sing Paul’s praises loud enough. Our appreciation for his help is unmeasurable. Thank you, Paul, and Backyard Plus for offering such outstanding service. Warmest Regards, Karen A., Tallahassee, FLOn 12/08/2023 by K. A. (verified customer)
Showing 91–120 of 272 results
-
Used on the 1995-1997 Hot Spot spas this fitting provided a flange for the cartridge-style heater element to seal against and a "dry-well" for the thermistor probe to slide into
-
This Heater High-Limit (red heater reset button) is the replacement for the Hot Spring Classic (Model D)
-
Sku: 10408
Receptacle, Jet Pump, Hot Spring
This jet pump receptacle mounts into the control box to provide an outlet to plug in the jet pump's power cord on the 1990-1996 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy & Sovereign spa models -
Sku: 74150
I2 C/RS485, 5-Port Comm Hub, IQ 2020
This 5 port I2C/RS485 adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug into the motherboard If you're adding on an IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light, etc , you'll need this ...read more -
This ozone receptacle was introduced in 1995 on the Hot Spring and Tiger River control boxes They were eliminated in the beginning of 1997, only to be added back in the early second quarter of 1997 This receptacle is no longer needed with the new style of ...read more
-
Sku: 71274
Jet Switch-2 Position, Hot Spring
This rotating jet switch is located in the control box of some pre-1988 Hot Spring spa models It is activated by rotating the "Jets" dial on or off on the exterior control panel -
Sku: 37089
Fuse SLOBLO 1/2A 250V 5x20in
This is a replacement fuse for the circulation pump line on IQ 2020 control boxes on all Hotsprings, Tiger River, and Limelight spas The fuse holder is mounted in the back of the control box near the circulation pump terminals on the circuit board A ...read more -
Kit includes both 6 3A and 8A fuse, 3pk each for Cool Zone
-
Sku: 34506
Fuseholder
Fuse holder houses the fuse for the older Freshwater II Ozonators and is also used to house the fuse for the circ pump circuit on IQ 2000 and IQ2020 control boxes -
Sku: 30189
Dimmer Switch, Hot Spring
This 115volt dimmer switch is used in pre-1990 Hot Spring spas This is one of two types used in Hot Spring spa models from 1980-1996 The second choice is the 10490 used in the 1990-1996 Hot Springs Note: Do not use a floodlight larger than 100 watts ...read more -
This screw is used for holding the IQ 2000 and IQ 2020 control boxes in place on the mounting bracket in Hotsprings, Tiger River, and Limelight spas
-
Sku: 36018
IQ Control Box Bracket
This aluminum bracket attaches to the spa door frame to enable the IQ Control Box to mount securely to this bracket The bracket does not come with the two 36898 screws that attach it to the control box Simple wood screws are used to attach it to the wood ...read more -
Sku: 34689
Capacitor Assembly, Hot Spot – Z
This capacitor was used on the Hot Spot Z (round) model after serial number Z-240132 (2nd quarter 1994) Note: For serial numbers prior to Z-240133 use part number 70838 upgrade kit -
Sku: 30168
Receptacle, Duplex – 15A 115V
This receptacle was used in the pre-1987 Hot Spring to provide power to the heater and the small circulation pump Power to this receptacle is turned on and off by the thermostat when the set temperature of the water falls or is reached -
Sku: 30105
Romex Clamp 3/4in
This clamp is used as strain relief is used to secure the heater's power cord to the bottom of the IQ Control box The strain relief prevents the cord from accidentally being disconnected from inside the control box should the cord be pulled down -
Sku: 75076
15 amp Mini Breaker, Hot Spot
This 15amp Mini Breaker is located on the control box on all 1993-1998 Hot Spot spa models This reset button is identified by the number 15 located on the round portion of the reset button -
Sku: 35196
Fuse, Freshwater II Ozonator
This is the fuse used to protect the Freshwater II Ozonator -
This is the power supply for the Eagle control box IQ 2020 spa control system for Rev D or newer
-
Sku: 75076-Generic
16 amp Mini Breaker, Hot Spot (After Market)
GENERIC (This does not come from Hot Spring factory and does not have a one year warranty) This generic replacement 15amp Mini Breaker is used to replace the original mini breaker located on the control box on all 1993-1998 Hot Spot spa models The reset ...read more -
Sku: 71618
Fuse, 25Amp 300V Type SC-25
Slo-blo fuse used on the 71584, 73859, 72469, and 76840 control boxes for the pump and heater circuits -
Sku: 34894
Jet Pump Receptacle
Jet Pump Receptacle (for two-speed pumps) used on Hot Spot spas prior to 1998 -
Sku: 75049
Mechanical, Timer, Hot Spring, Pre-1989
Mechanical timer is black with white timer pins Each pin represents a 15 minute interval When the pin(s) is pulled out at the desired time of day, the timer activates the jet pump for a daily filtration cycle on pre 1989 Hot Spring spas -
Sku: 75046
Quick Connect Terminal Kit
This kit includes 6 flag terminals and 6 screws used on the 70297 and the 70298 replacement relays -
This PWA Control Panel Interface board is only found on the 1995-1996 Tiger River Khyber, Manora and Tondi spa models It is located inside the control box
-
This wiring harness connects the electronic thermostat to the PWA Board on the backside of the 1995-1996 Tiger River Control Panel If there is a communication problem with this wiring harness there will be erratic heating issues in a 1995-1996 Tiger River ...read more
-
This 12Volt DC PWA Switch Relay controls the low-speed pump when the thermostat calls for heat on the 1995-1997 Hot Spot Z (round) and Y (rectangle shape) spa models Note: There should be 10v -19v DC between the two red wires coming from the thermostat in ...read more
-
The jet switch is located in the control box of all 1995-1998 Hot Spot spa models It is connected with a clear vinyl tube to the air button located on the bartop of the Hot Spot models Once the air button is depressed a puff of air activates this switch In ...read more
-
Cable connector assembly for Khyber
-
Sku: 34500
Fuse 1.5A 230V Slo-Blo
One of two fuses used on the 70821 circuit board To test this fuse, remove it from the board and check the resistance from end to end If the fuse is good, the fuse should test closed with no resistance If it is bad, it should show an open circuit
Showing 91–120 of 272 results