Thank you so much for helping me figure out my Vistabhot springs spa issue . The service call on the phone was fast, to the point and just excellent. Not only did Paul know what exact part I needed , he instructed me how to fix it ! and trouble shoot one more issue . This company is a great asset for the home owner that just needs a little extra help. Part delivery was on time and I saved tons of money on a service call . This is my go to place for any hot tub spa repairs ! Highly recommend to anyone and excellent nice service and nice people to talk to.,A+ and my wife’s happy !!On 05/21/2024 by J. S. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 15 results
-
Replaces the obsolete 39525 and obsolete 39204 Newly designed and includes o-ring This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 ...read more
-
Sku: 79006
Thermistor, Control Thermostat, Watkins No Fault Heater, Hot Spring, Tiger River and Limelight
Replaces the obsolete 39530 and obsolete 39205 Newly designed and includes o-ring This control thermistor is a safety device that measures the water temperature of your spa and communicates that temperature reading to the Motherboard It simply screws ...read more -
Replaces 38415 Newly designed and includes o-ring This control thermostat thermistor sensor detects the spa waters temperature and relays that information back to the system It simply screws into the No Fault Heater Housing (hand tight only) and plugs ...read more
-
Replaces 38416 Newly designed and includes o-ring This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws ...read more
-
Sku: 39192-X2-BYP
Power Jumper, Heater Relay Board, 2-pin
2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board -
Sku: 39193-X2-BYP
Power Jumpers, Heater Relay Board, 3-Pin (pkg of 2)
Package of two 3-pin metal jumpers is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style Heater Relay Board there are two of these 3 pin jumpers The jumpers are inserted flat on the top edge of the heater ...read more -
Sku: 39193
Power Jumper, Heater Relay Board, 3-Pin
The 3-pin metal jumper is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style heater relay board, there are two of these 3 pin jumpers The jumpers are inserted flat just above the gray terminal block numbered ...read more -
Sku: 39192
Power Jumper, Heater Relay Board, 2-Pin
This 2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board The 3-pin jumper is also used depending on the spa model and whether it's wired 120v or 240v -
Sku: 71377
Power Jumper, Terminal Block, IQ 2000
Jumpers used on the IQ 2000 control box terminal block for 120-volt operation or converting from 120 volt to 230 volt -
Sku: 71377-x3-BYP
Power Jumper, Terminal Block, IQ 2000
Kit of three jumpers used for configuring the voltage on the IQ2000 control system used from 1997 to 2000 on Hot Springs and Tiger River spa The configuration of the jumpers allows for conversion between 120 volt and 230 volt operation -
Sku: 39204
Thermistor, High-Limit, Hot Spring, Tiger River, Limelight
This item is obsolete and replaced by:
79005This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 39205
Thermistor, Control Thermostat, Hot Spring, Tiger River and Limelight
This item is obsolete and replaced by:
79006This control thermostat thermistor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 38415
Thermistor, Control Thermostat, Hot Spring and Tiger River
This item is obsolete and replaced by:
78970This control thermostat thermistor sensor detects the spa waters temperature and relays that information back to the system It simply screws into the No Fault Heater Housing (hand tight only) and plugs into the outside of the spa's control box If your ...read more -
Sku: 38416
Thermistor, High-Limit, Hot Spring and Tiger River
This item is obsolete and replaced by:
78969This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
OBSOLETE This is the replacement thermistor for all 1994 Hot Spring spa models and 1995-1998 Hot Spot RE, RLX, SE & SLX spa models This Control Thermostat Thermistor communicates the actual water temperature to the controller to shut off the heater ...read more
Showing all 15 results