Great serviceOn 04/19/2024 by H. P. (verified customer)
A thermistor is a semiconductor that changes resistance with temperature changes (as the temperature goes up, the resistance goes down). Tstats and High-limits can be found on older spas and have the same functionality as the Hi-limit/Control Thermistors.
Showing all 18 results
-
Replaces the obsolete 39525 and obsolete 39204 Newly designed and includes o-ring This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 ...read more
-
Sku: 79006
Thermistor, Control Thermostat, Watkins No Fault Heater, Hot Spring, Tiger River and Limelight
Replaces the obsolete 39530 and obsolete 39205 Newly designed and includes o-ring This control thermistor is a safety device that measures the water temperature of your spa and communicates that temperature reading to the Motherboard It simply screws ...read more -
Replaces 38415 Newly designed and includes o-ring This control thermostat thermistor sensor detects the spa waters temperature and relays that information back to the system It simply screws into the No Fault Heater Housing (hand tight only) and plugs ...read more
-
Replaces 38416 Newly designed and includes o-ring This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws ...read more
-
Sku: 34878
O-Ring, Control Thermistor
Control Thermostat Thermistor o-ring for the 79006 and 78970 thermistors This o-ring is located on the "inlet" side of the heater and is the larger of the two thermistor o-rings For the outlet side of the heater see the part# 34879 o-ring -
Sku: 34879
O-Ring, Hi-Limit Thermistor
High-Limit Thermistor o-ring for the 79005 and 78969 thermistors This o-ring is located on the "outlet" side of the heater and is the smaller of the two thermistor o-rings For the "inlet" side of the heater see part 34878 -
This control thermostat was mounted in the control box directly behind the temperature dial on all Hot Spring models from 1989-1993 It was mounted on the under the top-side control panel on all Tiger River models from 1992-1994
-
Sku: 33248
Hi-Limit, Spa, Tiger River and Hot Spot
This Spa Hi-Limit thermostat (red spa reset or tub reset button) is the factory replacement for the 1992-1994 Tiger River Khyber, Manora, and Tondi Also for the 1993-1994 Hot Spot Z model Notes: The Spa Hi-Limit is a safety device designed to shut off ...read more -
This wiring harness connects the electronic thermostat to the PWA Board on the backside of the 1995-1996 Tiger River Control Panel If there is a communication problem with this wiring harness there will be erratic heating issues in a 1995-1996 Tiger River ...read more
-
This wiring harness is used to connect the thermostat to the circuit board on the topside control panel on Tiger River spas made between 1992 and 1994
-
Sku: 34007
O-Ring, T-Stat Adapter, Tiger River
This o-ring is used on the t-stat adapter where the knob for adjusting the thermostat attaches to Tiger River control panels from 1992 to 1997 The stem from the thermostat sticks into this adapter and the knob on the control panel sits on the adapter -
Sku: 39204
Thermistor, High-Limit, Hot Spring, Tiger River, Limelight
This item is obsolete and replaced by:
79005This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 39205
Thermistor, Control Thermostat, Hot Spring, Tiger River and Limelight
This item is obsolete and replaced by:
79006This control thermostat thermistor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 38415
Thermistor, Control Thermostat, Hot Spring and Tiger River
This item is obsolete and replaced by:
78970This control thermostat thermistor sensor detects the spa waters temperature and relays that information back to the system It simply screws into the No Fault Heater Housing (hand tight only) and plugs into the outside of the spa's control box If your ...read more -
Sku: 38416
Thermistor, High-Limit, Hot Spring and Tiger River
This item is obsolete and replaced by:
78969This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This obsolete electronic high-limit is the replacement for the 1995-1996 Hot Spring Grandee, Highlife, ...read more
-
Sku: 85005-BYP
Control Box Components, Hot Spring
OBSOLETE This rebuild kit includes all the original components found inside the control box of a 1990-1993 Hot Spring Classic, Sovereign, Indoor-Outdoor, Prodigy, Home Spa and Jetsetter For those of us who want to start with a clean slate, everything ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This electronic thermostat is the replacement for the 1995-1996 Hot Spring Grandee, Highlife, Landmark, ...read more
Showing all 18 results