I would like to express how excellent this company is. I inherited a house with a 2007 Hotspring Aria hot tub. The spa hasn’t been operated in years and when I turned it on, it ran for about 10 minutes and died. I mean dead died. I knew absolutely nothing about hot tubs but with the excellent diagnosis videos, installation videos and superior phone support, I was able to replace the main control board, heater relay board, heater, circulation pump, the ozonator and all associated tubing. This took 4 1/2 hours over two days (I had to watch videos) but the spa runs like new! I had one question regarding the jumper voltage 18 or 12. I spoke with a technician and he was able to answer my question as well as helping me double check the voltages for the components on the relay board. I am handy with electronics and electricity and am comfortable working with 230 volts. Shipping was fast and as expected. I highly recommend BackYardPlus.On 06/28/2024 by F. R. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing 1–30 of 35 results
-
Sku: 77726-BUNDLE
Gecko IN.YJ 3 Series Complete System, 1999-2005 Hot Spot and Solana After-Market Retrofit
The Gecko IN YJ 3 Series complete system is the retrofit used on: Hot Spot 1999-2000 SE (Y); 1999-2002 RE (Z), RLX (Z/ZQ), SLX (Y/YQ); 2001-2002 SLXtra (W/WQ); 2003-2005 Sorrento (SOR/SORS), Tobago (TOB), Trinidad (TRI); 2010-2012 Dash (DAS) Solana ...read more -
Sku: 74723
Relay, IQ 2000 Control Box
This 30amp 18volt DC coil relay is used in the 1997 and 1998-2000 Hot Spring & Tiger River IQ 2000 Control Box There are two of these relays located in the upper left corner of the IQ 2000 control box One is the heater relay and one is the heater ...read more -
This is the replacement flow switch for the 1995-1996 Hot Spring Classic, Sovereign, Prodigy and Jetsetter spa models It is also the replacement for the 1995-1996 Tiger River Manora and Tondi spa models This low voltage flow switch monitors the flow of ...read more
-
Sku: 70297
Relay, DPST 110VDC Coil
This relay (or contactor) is also known as the Interlock Relay & Heater Relay is a 110VDC coil 30amp and was used on the 1990-1993 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy & Sovereign spa models Also used on the 1992-1994 Tiger River ...read more -
This is the replacement flow switch for the 1995-1996 Hot Spring 220 only Classic, Sovereign, Grandee, Highlife, Landmark and Summit spa models It is also the replacement for the 1995-1995 Tiger River Khyber spa model This low voltage switch is located in ...read more
-
Sku: 33263
Flow Switch, Tiger River
This is the replacement flow switch for the 1992-1994 Tiger River Khyber, Manora and Tondi spa models -
Sku: 34934
Fuse 2 Amp 250V
2 amp 250v fuse for the 1995-1998 Hot Spot RE, RLX, SE, and SLX spa models as well as the 2009 forward IQ 2020 control boxes -
Sku: 72361
Fuse, Freshwater III, 1/2A 250V FAST-BLO
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Small size fuse used in the Freshwater 3 Ozonator unit -
Sku: 70298
Relay, DPDT DC Coil
This double-pole/double-throw DC coil relay was used on the 1991-1993 Hot Spring Classic, Sovereign, Prodigy, Jetsetter, Highlife and Grandee spa models Used also on the 1992-1994 Tiger River Khyber spa model -
Sku: 34831
Flow Switch, Hot Spot
This is the replacement for the 1995-1997 Hot Spot Z model (round spa) and the Y model (rectangle spa) -
Sku: 34488
Relay, Power 30Amp 110Volt DC
This 30 amp 110-volt double-pole/single throw relay was used on the 1993-1994 Hot Spot Z (round) model and the 1994 Tiger River Khyber as a jet pump relay Check your serial number in the parts finder above to be sure this part is for your spa -
Sku: 33229
Air Switch (Latching), Hot Spot
This latching air switch was used for two different purposes on Hot Spot spa models In 1993-1994 is was used as a jet activation switch In 1995-1998 it was used as a light activation switch It is connected with a clear vinyl tube to the air button located ...read more -
Sku: 37089
Fuse SLOBLO 1/2A 250V 5x20in
This is a replacement fuse for the circulation pump line on IQ 2020 control boxes on all Hotsprings, Tiger River, and Limelight spas The fuse holder is mounted in the back of the control box near the circulation pump terminals on the circuit board A ...read more -
Kit includes both 6 3A and 8A fuse, 3pk each for Cool Zone
-
Sku: 34506
Fuseholder
Fuse holder houses the fuse for the older Freshwater II Ozonators and is also used to house the fuse for the circ pump circuit on IQ 2000 and IQ2020 control boxes -
Sku: 35196
Fuse, Freshwater II Ozonator
This is the fuse used to protect the Freshwater II Ozonator -
Sku: 71618
Fuse, 25Amp 300V Type SC-25
Slo-blo fuse used on the 71584, 73859, 72469, and 76840 control boxes for the pump and heater circuits -
This 12Volt DC PWA Switch Relay controls the low-speed pump when the thermostat calls for heat on the 1995-1997 Hot Spot Z (round) and Y (rectangle shape) spa models Note: There should be 10v -19v DC between the two red wires coming from the thermostat in ...read more
-
The jet switch is located in the control box of all 1995-1998 Hot Spot spa models It is connected with a clear vinyl tube to the air button located on the bartop of the Hot Spot models Once the air button is depressed a puff of air activates this switch In ...read more
-
Sku: 34500
Fuse 1.5A 230V Slo-Blo
One of two fuses used on the 70821 circuit board To test this fuse, remove it from the board and check the resistance from end to end If the fuse is good, the fuse should test closed with no resistance If it is bad, it should show an open circuit -
Sku: 33231
Relay, 20Amp SPST 110Volt DC
This 20amp single pole/single throw 110 volt DC relay was used 1993-1994 Hot Spot Z (round) model spa -
Sku: 302556
Fuse 2A 250V Slo-Blo
Replacement fuse found in the newest IQ 2020 control box on all 2012 5 Hot Spring and Limelight spas -
Sku: 70838
Capacitor Relay Upgrade Kit-Hot Spot Z
This upgrade kit is needed for the Hot Spot Z (round) model prior to Z-240133 (2nd quarter 1994) and comes with instructions for replacement from Z-330001 (3rd qtr 1993) to Z-240133 (2nd qtr 1994) Note: Factory photo shows that this includes a resistor ...read more -
Sku: 0965201
FUSE, 750MA 250V
This is the small fuse used in control boxes found in most Hot Spot brand spas with Gecko control systems in them The fuse is located usually in the top right corner of the circuit board near where the spa light connects to the circuit board -
Sku: 74140
15A-ATC/ATO Blade Fuse
15A-ATC/ATO blase fuse -
Sku: 74139
IA-3AG Fast Acting Fuse
IA-3AG fast-acting fuse -
This double-pole/double-throw 110 volt DC relay was used on the 1993-1994 Hot Spot Z (round) model spa
-
Sku: 34585
Slo-Blo Fuse, 1A 250V
Slo-Blo fuse, 1A 250V -
Sku: 33767
Relay, 30A 12VDC
Relay, 30A 12VDC, #PRD-7DG2-12
Showing 1–30 of 35 results