Best place ever, always goodOn 05/31/2024 by M. D. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing 1–30 of 41 results
-
Sku: 303550
Harness, LED Light
This LED light harness is used with item 303307 multicolored light and is apart of the retrofit replacement parts that include: 78448 Control Box 72093 Control Panel 77358 Heater 78451 Bracket 303307 LED Multi-Color Lightcross compatible with older ...read more -
Sku: 1178301-11
Power Supply, Points of Light LED’s, Limelight
This is the power supply (low voltage-5v) for the small LED lights (aka Points of Light, Raio) found on Limelight Spas -
This sensor fitting is installed through the side spa shell at the base of the hot tub near the suction and drain fittings on Hot Spot models beginning in 2020 Its purpose is to provide a watertight seal around the 72493 temperature control thermistor bulb
-
Sku: 76112
Thermistor Sensor Fitting, Hot Spot
This sensor fitting is installed through the side of the filter housing in all 1998-2005 Hot Spot brand spas Its purpose is to provide a watertight seal around the 71578 thermistor bulb -
Sku: 37727
Thermosensor Fitting, Solana
This thermo-sensor fitting is used to waterproof the temperature sensor (thermistor) that is located in the filter compartment of all Solana TX, RX and SX models -
Mounts in the control box on all Hot Spring models prior to 1997 that used a square receptacle The one-speed circulation pump (Silentflo 5000) plugs into this receptacle regardless of the voltage of your spa model All Hot Spring spa circulating pumps are ...read more
-
Used on the 1995-1997 Hot Spot spas this fitting provided a flange for the cartridge-style heater element to seal against and a "dry-well" for the thermistor probe to slide into
-
Sku: 10408
Receptacle, Jet Pump, Hot Spring
This jet pump receptacle mounts into the control box to provide an outlet to plug in the jet pump's power cord on the 1990-1996 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy & Sovereign spa models -
Sku: 75076
15 amp Mini Breaker, Hot Spot
This 15amp Mini Breaker is located on the control box on all 1993-1998 Hot Spot spa models This reset button is identified by the number 15 located on the round portion of the reset button -
This is the power supply for the Eagle control box IQ 2020 spa control system for Rev D or newer
-
Sku: 75076-Generic
16 amp Mini Breaker, Hot Spot (After Market)
GENERIC (This does not come from Hot Spring factory and does not have a one year warranty) This generic replacement 15amp Mini Breaker is used to replace the original mini breaker located on the control box on all 1993-1998 Hot Spot spa models The reset ...read more -
Sku: 34894
Jet Pump Receptacle
Jet Pump Receptacle (for two-speed pumps) used on Hot Spot spas prior to 1998 -
This wiring harness connects the electronic thermostat to the PWA Board on the backside of the 1995-1996 Tiger River Control Panel If there is a communication problem with this wiring harness there will be erratic heating issues in a 1995-1996 Tiger River ...read more
-
Cable connector assembly for Khyber
-
This is the power supply for the Hawk control box for Rev E or newer
-
Sku: 32452
Harness, Pcb 4T 115V 5Kw
Wiring harness for a 10-minute timer circuit board used on all models 1991 to 1993 Hot Springs spas The timer board is part number 71346 and is currently unavailable -
This 220volt heater receptacle is located in the 1995-1996, 220volt Tiger River Manora & Tondi control box It provides a place to plug in the heater Over the years, this item can fatigue and require replacement For the 120volt receptacle see part 35114
-
Sku: 71853
Cable Retrofit Kit, Hot Spring
The cable retrofit kit is used on the third through fourth quarter 1996 Hot Spring Landmark and Summit spas when upgrading from the original discontinued control box with the newer 1997 IQ2000 control box This cable is only necessary if the flow switch is ...read more -
Sku: 71741
Hotspot Power Cord
Hot Spot power cord -
Sku: 71280
Thermowell, Hot Spot Square
Thermowell houses the temperature sensor for Hot Spot Square -
Sku: 70899
Thermowell Assembly
Thermowell houses the thermistor probe on a 1995-1997 Hot Spot spa models -
This wiring harness is used to connect the thermostat to the circuit board on the topside control panel on Tiger River spas made between 1992 and 1994
-
Sku: 35112
Freshwater Ozone Receptacle, Tiger River
The female plug is installed in the control box and is used to plug in the Freshwater Ozonator on the Pre-1997 Tiger River Manora, Tondi & Khyber spa models -
Sku: 33421
Comm Cord, Tiger River Pre-1995
This communication cord looks like a Cat5 cable It communicates to the main control box circuit board (70374 or 70375) from the control panels PCB board in the 1992-1994 Tiger River Khyber, Manora & Tondi spa models -
Sku: 30170
Receptacle, Single – 20A 115V
Single receptacle, 20A 115V -
Sku: 34481
Screw Receptacle
Screw Receptacle -
Thermowell housing for the t-stat temperature probe to insert into This thermowell aka "drywell" keeps the copper t-stat probe away from the chlorinated water so it doesn't dissolve
-
Cool gray temperature sensor fitting
-
Sku: 30163
Heater Receptacle, Hot Spring
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This heater receptacle mounts in the control box on Hot Spring models from 1989-1996 It was used on the ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This 120volt heater receptacle is located in 1995-1996, 120volt Tiger River Manora & Tondi control ...read more
Showing 1–30 of 41 results