The team at Backyardplus.com are the best for anything Hot Springs. Super friendly and knowledgeable.On 06/05/2024 by S. O. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 11 results
-
Sku: 77726-BUNDLE
Gecko IN.YJ 3 Series Complete System, 1999-2005 Hot Spot and Solana After-Market Retrofit
The Gecko IN YJ 3 Series complete system is the retrofit used on: Hot Spot 1999-2000 SE (Y); 1999-2002 RE (Z), RLX (Z/ZQ), SLX (Y/YQ); 2001-2002 SLXtra (W/WQ); 2003-2005 Sorrento (SOR/SORS), Tobago (TOB), Trinidad (TRI); 2010-2012 Dash (DAS) Solana ...read more -
Heater connection wire kit, 8" long, 10 gauge wire, qty of 2 Connects from Hot Spot heater to board of S-Class series control box
-
Factory replacement control box with heater for the now obsolete 71584 control box used on the 1999-2002 Hot Spot RE, RLX, SE, SLX, and 2001-2002 SLXtra and the Solana 2000-2002 X (triangle shaped), 2003-2005 Solana RX, SX, and TX spa models Note ...read more
-
This jumper is used to bypass the pressure switch on the 2002-forward IQ 2020 spa control system The PDR Titanium Replacement Heater has its own automatic cut-off in the event of a low flow condition thus negating the need for a pressure switch After ...read more
-
This 12Volt DC PWA Switch Relay controls the low-speed pump when the thermostat calls for heat on the 1995-1997 Hot Spot Z (round) and Y (rectangle shape) spa models Note: There should be 10v -19v DC between the two red wires coming from the thermostat in ...read more
-
This upgrade kit is needed for the Hot Spot Z (round) model prior to Z-240133 (2nd quarter 1994) and comes with instructions for replacement From Z-330001 to Z-240133
-
Sku: 30201
Contactor 2PL208-240V A7730666
Contactor -
Sku: 30200
Contactor, 3 Pole 115Volt AC
This 3 Pole 115Volt AC Coil was used on the older Hot Spring Classic and Indoor/Outdoor spa models -
Sku: 70797
Resistor, Hot Spot
Obsolete: No factory suggested replacement available at this time Please contact our technicians at (805) 541-9000 or wizard@backyardplus com for advice This resistor was only used on the 1993-1994 Hot Spot Z (round) model spa Most Watkins Techs ...read more -
Sku: 75059
Contactor, DP DC Coil
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This DC power relay replaces defective DC contactors (P/N 10298) in the first and second quarter 1990 ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Heater control box assembly, Tiger River Manora and Sumatran
Showing all 11 results