I would like to express how excellent this company is. I inherited a house with a 2007 Hotspring Aria hot tub. The spa hasn’t been operated in years and when I turned it on, it ran for about 10 minutes and died. I mean dead died. I knew absolutely nothing about hot tubs but with the excellent diagnosis videos, installation videos and superior phone support, I was able to replace the main control board, heater relay board, heater, circulation pump, the ozonator and all associated tubing. This took 4 1/2 hours over two days (I had to watch videos) but the spa runs like new! I had one question regarding the jumper voltage 18 or 12. I spoke with a technician and he was able to answer my question as well as helping me double check the voltages for the components on the relay board. I am handy with electronics and electricity and am comfortable working with 230 volts. Shipping was fast and as expected. I highly recommend BackYardPlus.On 06/28/2024 by F. R. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 15 results
-
Sku: 77726-BUNDLE
Gecko IN.YJ 3 Series Complete System, 1999-2005 Hot Spot and Solana After-Market Retrofit
The Gecko IN YJ 3 Series complete system is the retrofit used on: Hot Spot 1999-2000 SE (Y); 1999-2002 RE (Z), RLX (Z/ZQ), SLX (Y/YQ); 2001-2002 SLXtra (W/WQ); 2003-2005 Sorrento (SOR/SORS), Tobago (TOB), Trinidad (TRI); 2010-2012 Dash (DAS) Solana ...read more -
Sku: 303550
Harness, LED Light
This LED light harness is used with item 303307 multicolored light and is apart of the retrofit replacement parts that include: 78448 Control Box 72093 Control Panel 77358 Heater 78451 Bracket 303307 LED Multi-Color Lightcross compatible with older ...read more -
Sku: 303307
LED Light, Multicolor, Hot Spot and Solana
This multicolor LED light is used with 78448 control box and is apart of the retrofit replacements parts listed below: 78448 Control Box 72093 Control Panel 77358 Heater 78451 Bracket 303307 LED Multi-Color Lightcross compatible with older control ...read more -
Heater connection wire kit, 8" long, 10 gauge wire, qty of 2 Connects from Hot Spot heater to board of S-Class series control box
-
Factory replacement control box with heater for the now obsolete 71584 control box used on the 1999-2002 Hot Spot RE, RLX, SE, SLX, and 2001-2002 SLXtra and the Solana 2000-2002 X (triangle shaped), 2003-2005 Solana RX, SX, and TX spa models Note ...read more
-
This jumper is used to bypass the pressure switch on the 2002-forward IQ 2020 spa control system The PDR Titanium Replacement Heater has its own automatic cut-off in the event of a low flow condition thus negating the need for a pressure switch After ...read more
-
This Hot Spot heater electronic pressure switch is a safety device that will shut down the heater if a "low water flow" condition occurs It is used on Hot Spot models (except Sprint & Dash models) and Solana spa models Some symptoms of failure include ...read more
-
This after-market heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
This Hot Spot heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
Sku: 36021
Program Jumper
This program jumpers can be found on the motherboard of all IQ 2000 and IQ 2020 Control Boxes Also used on the Interlock Timer Board (70821) -
This pressure switch is a safety device that screws into the heater and connects to the control box's main circuit board The main circuit board (motherboard) will shut down the heater if a "low water flow" condition occurs as monitored by this pressure ...read more
-
Sku: 36021-x4-BYP
Program Jumpers (Qty of 4)
(Quantity of 4) Pack of program jumpers used on the motherboards of all IQ 2000 and 2001-2009 5 IQ 2020 Control Boxes Also used on the Interlock Timer Board ( 70821 ) -
Sku: 33232
Pressure Switch, Hot Spot
This replacement pressure switch is for the 1993-1994 Hot Spot Z (round spa) as well as the 1998 Hot Spot RE, RLX, SE, and SLX Notes: When the pressure switch senses proper water flow, the switch remains closed However, if the pressure switch senses a ...read more -
Sku: 32337
Jet Switch, Hot Spring
Jet switch for the Hot Spring 1991-1996 Classic, Grandee, Highlife, Jetsetter, Prodigy and Sovereign and 1995 through 2nd quarter 1996 Landmark & Summit spa models This switch mounts inside the control box directly behind the front control panel and is ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Heater control box assembly, Tiger River Manora and Sumatran
Showing all 15 results