It was very easy to select the corret parts for my "serial Number". All parts were correct and operated as required.On 06/20/2024 by M. R. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 24 results
-
This OEM replacement IQ 2020 control board (motherboard) is for all IQ 2020 Control Boxes (77271) found on all 2001-2009 5 Hot Spring, Tiger River and Limelight spa models It is used on domestic 60hz model spas only
-
This OEM replacement IQ 2020 control board is for the Orca Box (76082) which has the Invensys circuitry, 115/220 VAC, used on 2009 Phase 2 through 3rd Quarter 2012 Hot Spring, Tiger River, and Limelight If your circuitry is marked with a blue label that says ...read more
-
This jumper is used to bypass the pressure switch on the 2002-forward IQ 2020 spa control system The PDR Titanium Replacement Heater has its own automatic cut-off in the event of a low flow condition thus negating the need for a pressure switch After ...read more
-
This Hot Spot heater electronic pressure switch is a safety device that will shut down the heater if a "low water flow" condition occurs It is used on Hot Spot models (except Sprint & Dash models) and Solana spa models Some symptoms of failure include ...read more
-
This after-market heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
This Hot Spot heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
This sensor fitting is installed through the side spa shell at the base of the hot tub near the suction and drain fittings on Hot Spot models beginning in 2020 Its purpose is to provide a watertight seal around the 72493 temperature control thermistor bulb
-
Sku: 76112
Thermistor Sensor Fitting, Hot Spot
This sensor fitting is installed through the side of the filter housing in all 1998-2005 Hot Spot brand spas Its purpose is to provide a watertight seal around the 71578 thermistor bulb -
This pressure switch is a safety device that screws into the heater and connects to the control box's main circuit board The main circuit board (motherboard) will shut down the heater if a "low water flow" condition occurs as monitored by this pressure ...read more
-
Sku: 37727
Thermosensor Fitting, Solana
This thermo-sensor fitting is used to waterproof the temperature sensor (thermistor) that is located in the filter compartment of all Solana TX, RX and SX models -
Sku: 33232
Pressure Switch, Hot Spot
This replacement pressure switch is for the 1993-1994 Hot Spot Z (round spa) as well as the 1998 Hot Spot RE, RLX, SE, and SLX Notes: When the pressure switch senses proper water flow, the switch remains closed However, if the pressure switch senses a ...read more -
Used on the 1995-1997 Hot Spot spas this fitting provided a flange for the cartridge-style heater element to seal against and a "dry-well" for the thermistor probe to slide into
-
This PWA Control Panel Interface board is only found on the 1995-1996 Tiger River Khyber, Manora and Tondi spa models It is located inside the control box
-
Sku: 71974
PWA Main Circuit Board, Hot Spot
This PWA Main Circuit Board is the factory replacement for the 1998 Hot Spot RE, RLX (round), SE and SLX (square) models The picture may differ slightly from your circuit board due to revisions but this board will be a "Plug 'N Play" replacement -
Sku: 32452
Harness, Pcb 4T 115V 5Kw
Wiring harness for a 10-minute timer circuit board used on all models 1991 to 1993 Hot Springs spas The timer board is part number 71346 and is currently unavailable -
Sku: 71280
Thermowell, Hot Spot Square
Thermowell houses the temperature sensor for Hot Spot Square -
Sku: 70899
Thermowell Assembly
Thermowell houses the thermistor probe on a 1995-1997 Hot Spot spa models -
Thermowell housing for the t-stat temperature probe to insert into This thermowell aka "drywell" keeps the copper t-stat probe away from the chlorinated water so it doesn't dissolve
-
Cool gray temperature sensor fitting
-
Sku: 35201
Diode Assembly, Piggyback
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Diode Assembly, Piggyback -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This main circuit board is for the 1992-1994 Tiger River Khyber wired 220volt
-
Sku: 34933
Inline Fuseholder, Hot Spot
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Inline fuse holder for the 1995-1998 Hot Spot RE, RLX, SE, and SLX spa models -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This 115 volt main circuit board is for the 1992-1994 Tiger River Manora and Tondi models This 115volt ...read more
-
Recently released for sale by the factory, this OEM replacement motherboard is for the Orca Box (Invensys Circuitry) (76082), 115/220 VAC, used on 2009 Phase 2 through 3rd Quarter 2012 Hot Spring, Tiger River, and Limelight
Showing all 24 results