quick ship ,as described and was perfect transaction. ThanksOn 06/13/2024 by B. H. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 12 results
-
Sku: 30-01395-K
Thermistor Adapters, After-Market
The after-market thermistor adapters work to allow the after-market thermistors to connect to the outside of the control box instead of connecting directly to the motherboard of the control box -
Sku: 30208
Hi-Limit, Spa, 120 Degree, Hot Spring
This Spa Hi-Limit thermostat (aka spa reset or tub reset) is a safety device designed to prevent damage to the spa that would occur if the spa overheated The probe of this high-limit resides in a "drywell" along with the thermostat probe The spa high-limit ...read more -
Sku: 10489
Bridge Wave Rectifier
This rectifier was used on the 1990-1993 Hot Spring Classic, Sovereign, Prodigy, Jetsetter, Highlife and Grandee, 1994 Tiger River Khyber and the 1993-1994 Hot Spot Z model -
Sku: 34806
Hi-Limit, Spa, Hot Spot
This Spa High-Limit ( red spa reset or tub reset button) is a safety device designed to shut off all power to the spa should the water temperature reach 120 degrees (plus or minus 4 degrees F) This will prevent damage to the spa or injury to bathers from ...read more -
Sku: 33248
Hi-Limit, Spa, Tiger River and Hot Spot
This Spa Hi-Limit thermostat (red spa reset or tub reset button) is the factory replacement for the 1992-1994 Tiger River Khyber, Manora, and Tondi Also for the 1993-1994 Hot Spot Z model Notes: The Spa Hi-Limit is a safety device designed to shut off ...read more -
This Heater High-Limit (red heater reset button) is the replacement for the Hot Spring Classic (Model D)
-
Sku: 33920
Timer Chip, 10 Min. Delay, Hot Spot
The 10 Minute Timer Delay is designed to cause the "heating mode" in the 1993-1994 Hot Spot Z model (round spa) to wait for 10 minutes before engaging This device is utilized whenever the spa is powered up or when the spa's jet pump is turned off This gives ...read more -
The circulation pump timer board operates the "Summer Timer" mode in the 120 volt 1996 Hot Spring and Tiger River spas
-
Sku: 30209
Hi-Limit, Heater, 150 degree, Hot Spring
OBSOLETE: This Heater Hi-Limit (red "heater reset" button) is designed to kill power to the heater if the core temperature exceeds 150 deg The probe of this high-limit is inserted into the end of the heater element and surrounded with plumbers putty to ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This PWA: Interlock Timer Circuit Board is the factory replacement for all 1994-1996 Hot Spring Classic, ...read more
-
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This obsolete electronic high-limit is the replacement for the 1995-1996 Hot Spring Grandee, Highlife, ...read more
-
Sku: 71346
Timer Board, 10 Min., Hot Spring
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This factory replacement jet pump timer board is for the 1991-1993 Hot Spring Classic, Grandee, ...read more
Showing all 12 results