Thank you so much for helping me figure out my Vistabhot springs spa issue . The service call on the phone was fast, to the point and just excellent. Not only did Paul know what exact part I needed , he instructed me how to fix it ! and trouble shoot one more issue . This company is a great asset for the home owner that just needs a little extra help. Part delivery was on time and I saved tons of money on a service call . This is my go to place for any hot tub spa repairs ! Highly recommend to anyone and excellent nice service and nice people to talk to.,A+ and my wife’s happy !!On 05/21/2024 by J. S. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing 1–30 of 35 results
-
This jumper is used to bypass the pressure switch on the 2002-forward IQ 2020 spa control system The PDR Titanium Replacement Heater has its own automatic cut-off in the event of a low flow condition thus negating the need for a pressure switch After ...read more
-
Replaces the obsolete 39525 and obsolete 39204 Newly designed and includes o-ring This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 ...read more
-
Sku: 79006
Thermistor, Control Thermostat, Watkins No Fault Heater, Hot Spring, Tiger River and Limelight
Replaces the obsolete 39530 and obsolete 39205 Newly designed and includes o-ring This control thermistor is a safety device that measures the water temperature of your spa and communicates that temperature reading to the Motherboard It simply screws ...read more -
Replaces 38415 Newly designed and includes o-ring This control thermostat thermistor sensor detects the spa waters temperature and relays that information back to the system It simply screws into the No Fault Heater Housing (hand tight only) and plugs ...read more
-
Replaces 38416 Newly designed and includes o-ring This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws ...read more
-
This newly designed high limit thermistor replaces the original black plastic-tipped version It is a safety device that will shut down power to the spa if the water temperature exiting the heater is too hot This would indicate a "low water flow" condition ...read more
-
This Control Thermostat Thermistor communicates the actual water temperature to the controller (control box motherboard) to shut off the heater when the spa reaches the target temperature It is used on all 73859, 72469, 76840 and 76091 control boxes
-
Sku: 34-01395-K
Thermistor, Control & Hi-Limit Sensor Kit, After Market
The after-market thermistor kit (1 control and 1 hi-limit sensor included with o-rings as well as adapters) that fit with either the 4kW or 6kW after-market PDR Titanium double-barrel heater These sensors can plug in directly to the motherboard located ...read more -
Sku: 30-01395-K
Thermistor Adapters, After-Market
The after-market thermistor adapters work to allow the after-market thermistors to connect to the outside of the control box instead of connecting directly to the motherboard of the control box -
This Hot Spot heater electronic pressure switch is a safety device that will shut down the heater if a "low water flow" condition occurs It is used on Hot Spot models (except Sprint & Dash models) and Solana spa models Some symptoms of failure include ...read more
-
Sku: 1306501
Power jumper, 2 pin, 15mm, Hawk
This 2 pin jumper is used in the Cedric Control box (73859) as well as the Hawk control box (76840) for Hot Spot tubs -
Sku: 39192-X2-BYP
Power Jumper, Heater Relay Board, 2-pin
2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board -
Sku: 39193-X2-BYP
Power Jumpers, Heater Relay Board, 3-Pin (pkg of 2)
Package of two 3-pin metal jumpers is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style Heater Relay Board there are two of these 3 pin jumpers The jumpers are inserted flat on the top edge of the heater ...read more -
Sku: 39193
Power Jumper, Heater Relay Board, 3-Pin
The 3-pin metal jumper is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style heater relay board, there are two of these 3 pin jumpers The jumpers are inserted flat just above the gray terminal block numbered ...read more -
This after-market heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
This Hot Spot heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
This is the after-market replacement thermistor for the 1999-2002 Hot Spot RE, RLX, SE, SLX, and the 2001-2002 SLXtra (wood-sided) spa models Also the Solana 2000-2002 X, 2003-2005 RX, SX, and TX models This thermistor communicates the actual water ...read more
-
This is the replacement thermistor for the 1999-2002 Hot Spot RE, RLX, SE, SLX, and the 2001-2002 SLXtra (wood-sided) spa models Also the Solana 2000-2002 X, 2003-2005 RX, SX, and TX models This thermistor communicates the actual water temperature to the ...read more
-
Sku: 39192
Power Jumper, Heater Relay Board, 2-Pin
This 2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board The 3-pin jumper is also used depending on the spa model and whether it's wired 120v or 240v -
This pressure switch is a safety device that screws into the heater and connects to the control box's main circuit board The main circuit board (motherboard) will shut down the heater if a "low water flow" condition occurs as monitored by this pressure ...read more
-
Sku: 71377
Power Jumper, Terminal Block, IQ 2000
Jumpers used on the IQ 2000 control box terminal block for 120-volt operation or converting from 120 volt to 230 volt -
Sku: 71377-x3-BYP
Power Jumper, Terminal Block, IQ 2000
Kit of three jumpers used for configuring the voltage on the IQ2000 control system used from 1997 to 2000 on Hot Springs and Tiger River spa The configuration of the jumpers allows for conversion between 120 volt and 230 volt operation -
Sku: 33232
Pressure Switch, Hot Spot
This replacement pressure switch is for the 1993-1994 Hot Spot Z (round spa) as well as the 1998 Hot Spot RE, RLX, SE, and SLX Notes: When the pressure switch senses proper water flow, the switch remains closed However, if the pressure switch senses a ...read more -
Sku: 33229
Air Switch (Latching), Hot Spot
This latching air switch was used for two different purposes on Hot Spot spa models In 1993-1994 is was used as a jet activation switch In 1995-1998 it was used as a light activation switch It is connected with a clear vinyl tube to the air button located ...read more -
The jet switch is located in the control box of all 1995-1998 Hot Spot spa models It is connected with a clear vinyl tube to the air button located on the bartop of the Hot Spot models Once the air button is depressed a puff of air activates this switch In ...read more
-
Sku: 008019
Sensor Set, Oasis
High-limit and control thermostat sensor set for the Oasis spa models -
Sku: 39204
Thermistor, High-Limit, Hot Spring, Tiger River, Limelight
This item is obsolete and replaced by:
79005This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 39205
Thermistor, Control Thermostat, Hot Spring, Tiger River and Limelight
This item is obsolete and replaced by:
79006This control thermostat thermistor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 38415
Thermistor, Control Thermostat, Hot Spring and Tiger River
This item is obsolete and replaced by:
78970This control thermostat thermistor sensor detects the spa waters temperature and relays that information back to the system It simply screws into the No Fault Heater Housing (hand tight only) and plugs into the outside of the spa's control box If your ...read more
Showing 1–30 of 35 results