CONTROL BOXES

These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.

Electrical: Assembly Kit, Diode Assembly, Grounding Bar, O Ring, Pressure Switch, Rectifier

Showing all 16 results

  • Hot Spot Heater Ground Bar, Gecko S-Class Series After-Market Heater
    Grounding bar for the Hot Spot heater (after-market Gecko S-Class) 5 Position, 14-6 AWG This grounding bar is attached to the heater on Hot Spot and Solana brand spas and allows the pump and other accessories to have a secondary ground tied into the ...read more
    $5.82
    Add to cart
  • Pressure Switch Bypass Jumper, IQ 2020 Spa Control System
    This jumper is used to bypass the pressure switch on the 2002-forward IQ 2020 spa control system The PDR Titanium Replacement Heater has its own automatic cut-off in the event of a low flow condition thus negating the need for a pressure switch After ...read more
    $29.30
    Add to cart
  • O-Ring, Control Thermistor
    Control Thermostat Thermistor o-ring for the 79006 and 78970 thermistors This o-ring is located on the "inlet" side of the heater and is the larger of the two thermistor o-rings For the outlet side of the heater see the part# 34879 o-ring
    $1.74
    Add to cart
  • O-Ring, Hi-Limit Thermistor
    High-Limit Thermistor o-ring for the 79005 and 78969 thermistors This o-ring is located on the "outlet" side of the heater and is the smaller of the two thermistor o-rings For the "inlet" side of the heater see part 34878
    $1.63
    Add to cart
  • Electronic Pressure Switch, Solana and Hot Spot Heater
    This Hot Spot heater electronic pressure switch is a safety device that will shut down the heater if a "low water flow" condition occurs It is used on Hot Spot models (except Sprint & Dash models) and Solana spa models   Some symptoms of failure include ...read more
    $60.35
    Add to cart
  • Pressure Switch, After-Market, Solana and Hot Spot Heater
    This after-market heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
    $27.36 View OEM
    Add to cart
  • Pressure Switch, Solana and Hot Spot Heater
    This Hot Spot heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
    $47.26 View Generic
    Add to cart
  • Bridge Wave Rectifier
    This rectifier was used on the 1990-1993 Hot Spring Classic, Sovereign, Prodigy, Jetsetter, Highlife and Grandee, 1994 Tiger River Khyber and the 1993-1994 Hot Spot Z model
    $16.82
    Add to cart
  • Pressure Switch, Hot Spot Sprint and Dash
    This pressure switch is a safety device that screws into the heater and connects to the control box's main circuit board The main circuit board (motherboard) will shut down the heater if a "low water flow" condition occurs as monitored by this pressure ...read more
    $27.60
    Add to cart
  • Pressure Switch, Hot Spot
    This replacement pressure switch is for the 1993-1994 Hot Spot Z (round spa) as well as the 1998 Hot Spot RE, RLX, SE, and SLX Notes: When the pressure switch senses proper water flow, the switch remains closed However, if the pressure switch senses a ...read more
    $53.82
    Add to cart
  • Pushbutton Air Switch, White
    This white colored air push button is located on the bar top on the Hot Spot spa models Once the air button is depressed, a puff of air activates the jet switch located in the control box In turn the switch sends a signal to the circuit board which turns ...read more
    $14.11
    Add to cart
  • Connector Assembly Cable Kyber and Siberian
    Cable connector assembly for Khyber
    $24.08
    Add to cart
  • Capacitor Relay Upgrade Kit-Hot Spot Z
    This upgrade kit is needed for the Hot Spot Z (round) model prior to Z-240133 (2nd quarter 1994) and comes with instructions for replacement from Z-330001 (3rd qtr 1993) to Z-240133 (2nd qtr 1994) Note: Factory photo shows that this includes a resistor ...read more
    $105.03
    Add to cart
  • O-Ring, T-Stat Adapter, Tiger River
    This o-ring is used on the t-stat adapter where the knob for adjusting the thermostat attaches to Tiger River control panels from 1992 to 1997   The stem from the thermostat sticks into this adapter and the knob on the control panel sits on the adapter
    $8.25
    Add to cart
  • Diode Assembly, Piggyback
    Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Diode Assembly, Piggyback
  • Harness Assembly Coil Driver Z
    Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Harness Assembly Coil Driver Z

Showing all 16 results