The team at Backyardplus.com are the best for anything Hot Springs. Super friendly and knowledgeable.On 06/05/2024 by S. O. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 21 results
-
Sku: 77726-BUNDLE
Gecko IN.YJ 3 Series Complete System, 1999-2005 Hot Spot and Solana After-Market Retrofit
The Gecko IN YJ 3 Series complete system is the retrofit used on: Hot Spot 1999-2000 SE (Y); 1999-2002 RE (Z), RLX (Z/ZQ), SLX (Y/YQ); 2001-2002 SLXtra (W/WQ); 2003-2005 Sorrento (SOR/SORS), Tobago (TOB), Trinidad (TRI); 2010-2012 Dash (DAS) Solana ...read more -
Sku: 303550
Harness, LED Light
This LED light harness is used with item 303307 multicolored light and is apart of the retrofit replacement parts that include: 78448 Control Box 72093 Control Panel 77358 Heater 78451 Bracket 303307 LED Multi-Color Lightcross compatible with older ...read more -
Sku: 303307
LED Light, Multicolor, Hot Spot and Solana
This multicolor LED light is used with 78448 control box and is apart of the retrofit replacements parts listed below: 78448 Control Box 72093 Control Panel 77358 Heater 78451 Bracket 303307 LED Multi-Color Lightcross compatible with older control ...read more -
Sku: 1306501
Power jumper, 2 pin, 15mm, Hawk
This 2 pin jumper is used in the Cedric Control box (73859) as well as the Hawk control box (76840) for Hot Spot tubs -
Sku: 39192-X2-BYP
Power Jumper, Heater Relay Board, 2-pin
2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board -
Sku: 39193-X2-BYP
Power Jumpers, Heater Relay Board, 3-Pin (pkg of 2)
Package of two 3-pin metal jumpers is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style Heater Relay Board there are two of these 3 pin jumpers The jumpers are inserted flat on the top edge of the heater ...read more -
Sku: 39193
Power Jumper, Heater Relay Board, 3-Pin
The 3-pin metal jumper is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style heater relay board, there are two of these 3 pin jumpers The jumpers are inserted flat just above the gray terminal block numbered ...read more -
Sku: 39192
Power Jumper, Heater Relay Board, 2-Pin
This 2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board The 3-pin jumper is also used depending on the spa model and whether it's wired 120v or 240v -
This sensor fitting is installed through the side spa shell at the base of the hot tub near the suction and drain fittings on Hot Spot models beginning in 2020 Its purpose is to provide a watertight seal around the 72493 temperature control thermistor bulb
-
Sku: 76112
Thermistor Sensor Fitting, Hot Spot
This sensor fitting is installed through the side of the filter housing in all 1998-2005 Hot Spot brand spas Its purpose is to provide a watertight seal around the 71578 thermistor bulb -
Sku: 37727
Thermosensor Fitting, Solana
This thermo-sensor fitting is used to waterproof the temperature sensor (thermistor) that is located in the filter compartment of all Solana TX, RX and SX models -
Sku: 71377
Power Jumper, Terminal Block, IQ 2000
Jumpers used on the IQ 2000 control box terminal block for 120-volt operation or converting from 120 volt to 230 volt -
Sku: 71377-x3-BYP
Power Jumper, Terminal Block, IQ 2000
Kit of three jumpers used for configuring the voltage on the IQ2000 control system used from 1997 to 2000 on Hot Springs and Tiger River spa The configuration of the jumpers allows for conversion between 120 volt and 230 volt operation -
Used on the 1995-1997 Hot Spot spas this fitting provided a flange for the cartridge-style heater element to seal against and a "dry-well" for the thermistor probe to slide into
-
Sku: 75076
15 amp Mini Breaker, Hot Spot
This 15amp Mini Breaker is located on the control box on all 1993-1998 Hot Spot spa models This reset button is identified by the number 15 located on the round portion of the reset button -
Sku: 75076-Generic
16 amp Mini Breaker, Hot Spot (After Market)
GENERIC (This does not come from Hot Spring factory and does not have a one year warranty) This generic replacement 15amp Mini Breaker is used to replace the original mini breaker located on the control box on all 1993-1998 Hot Spot spa models The reset ...read more -
Sku: 32452
Harness, Pcb 4T 115V 5Kw
Wiring harness for a 10-minute timer circuit board used on all models 1991 to 1993 Hot Springs spas The timer board is part number 71346 and is currently unavailable -
Sku: 71280
Thermowell, Hot Spot Square
Thermowell houses the temperature sensor for Hot Spot Square -
Sku: 70899
Thermowell Assembly
Thermowell houses the thermistor probe on a 1995-1997 Hot Spot spa models -
Thermowell housing for the t-stat temperature probe to insert into This thermowell aka "drywell" keeps the copper t-stat probe away from the chlorinated water so it doesn't dissolve
-
Cool gray temperature sensor fitting