I would like to express how excellent this company is. I inherited a house with a 2007 Hotspring Aria hot tub. The spa hasn’t been operated in years and when I turned it on, it ran for about 10 minutes and died. I mean dead died. I knew absolutely nothing about hot tubs but with the excellent diagnosis videos, installation videos and superior phone support, I was able to replace the main control board, heater relay board, heater, circulation pump, the ozonator and all associated tubing. This took 4 1/2 hours over two days (I had to watch videos) but the spa runs like new! I had one question regarding the jumper voltage 18 or 12. I spoke with a technician and he was able to answer my question as well as helping me double check the voltages for the components on the relay board. I am handy with electronics and electricity and am comfortable working with 230 volts. Shipping was fast and as expected. I highly recommend BackYardPlus.On 06/28/2024 by F. R. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing 1–30 of 36 results
-
Sku: 77119
IQ 2020 Heater Relay Board
This IQ2020 Heater Relay Circuit Board is the newest revision for the 2001-2009 5 IQ2020 Control Box It's upgraded design provides a more efficient method of connecting the heater's power cord to this board, therefore, reducing fatigue on the two "beefed up" ...read more -
This is the IQ 2020 heater relay board compatible with the Eagle IQ 2020 spa control system for all forward Hot Spring and Limelight models as well as Tiger River spa retrofits Reference: 1302801-1
-
This IQ 2020 heater relay board replaces the now obsolete 76071 (Orca with Invensys Circuitry) This IQ 2020 heater relay board is for the 2009 5 to 2012 5 Hot Spring, Tiger River and Limelight spa models using the Orca (Invensys control box system) For ...read more
-
Sku: 74723
Relay, IQ 2000 Control Box
This 30amp 18volt DC coil relay is used in the 1997 and 1998-2000 Hot Spring & Tiger River IQ 2000 Control Box There are two of these relays located in the upper left corner of the IQ 2000 control box One is the heater relay and one is the heater ...read more -
This control thermostat was mounted in the control box directly behind the temperature dial on all Hot Spring models from 1989-1993 It was mounted on the under the top-side control panel on all Tiger River models from 1992-1994
-
This is the replacement flow switch for the 1995-1996 Hot Spring Classic, Sovereign, Prodigy and Jetsetter spa models It is also the replacement for the 1995-1996 Tiger River Manora and Tondi spa models This low voltage flow switch monitors the flow of ...read more
-
Sku: 70297
Relay, DPST 110VDC Coil
This relay (or contactor) is also known as the Interlock Relay & Heater Relay is a 110VDC coil 30amp and was used on the 1990-1993 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy & Sovereign spa models Also used on the 1992-1994 Tiger River ...read more -
Sku: 33249
Thermostat, Control, Hot Spot
This Control Thermostat is the replacement for the 1993-1994 Hot Spot Z (round spa) spa model -
This is the replacement flow switch for the 1995-1996 Hot Spring 220 only Classic, Sovereign, Grandee, Highlife, Landmark and Summit spa models It is also the replacement for the 1995-1995 Tiger River Khyber spa model This low voltage switch is located in ...read more
-
Sku: 33263
Flow Switch, Tiger River
This is the replacement flow switch for the 1992-1994 Tiger River Khyber, Manora and Tondi spa models -
Sku: 70298
Relay, DPDT DC Coil
This double-pole/double-throw DC coil relay was used on the 1991-1993 Hot Spring Classic, Sovereign, Prodigy, Jetsetter, Highlife and Grandee spa models Used also on the 1992-1994 Tiger River Khyber spa model -
Sku: 34831
Flow Switch, Hot Spot
This is the replacement for the 1995-1997 Hot Spot Z model (round spa) and the Y model (rectangle spa) -
Sku: 34488
Relay, Power 30Amp 110Volt DC
This 30 amp 110-volt double-pole/single throw relay was used on the 1993-1994 Hot Spot Z (round) model and the 1994 Tiger River Khyber as a jet pump relay Check your serial number in the parts finder above to be sure this part is for your spa -
Cable connector assembly for Khyber
-
Sku: 33231
Relay, 20Amp SPST 110Volt DC
This 20amp single pole/single throw 110 volt DC relay was used 1993-1994 Hot Spot Z (round) model spa -
Sku: 37723
Terminal Block, Hot Spot
Terminal Block, Hot Spot, 1998 This Terminal Block is part of the 1998 Hot Spot Control Box Assembly (Complete Control Box Part 37335) It is found on the 1998 Hot Spot RE, RLX, SE, SLX, and SLXtra spa models -
Sku: 71986
Rj-12 Phone Connector, 25 Pack
25 Pack of the connectors that go on the end of the cable for the replacement aux panels for spas made beginning in 1998 -
Sku: 70838
Capacitor Relay Upgrade Kit-Hot Spot Z
This upgrade kit is needed for the Hot Spot Z (round) model prior to Z-240133 (2nd quarter 1994) and comes with instructions for replacement from Z-330001 (3rd qtr 1993) to Z-240133 (2nd qtr 1994) Note: Factory photo shows that this includes a resistor ...read more -
This double-pole/double-throw 110 volt DC relay was used on the 1993-1994 Hot Spot Z (round) model spa
-
Sku: 71129
Test Leads, Pomona 5682 Black
TEST LEADS, POMONA 5682 BLACK -
Sku: 71131
Test Leads, Pomona 5682 Red
Test lead, Pomona 5682, Red -
Sku: 33767
Relay, 30A 12VDC
Relay, 30A 12VDC, #PRD-7DG2-12 -
Sku: 34321
Relay, DPST 30A 12Volt DC
This 30amp double pole/single throw 12volt coil relay was used for various purposes Used for a light, heater, interlock, low-speed jet pump, high-speed jet pump, and circulation pump relay in all 1994-1996 Hot Spring, all 1995-1998 Hot Spot, and all ...read more -
OBSOLETE This Electronic Control Thermostat (thermistor included) replaces the mechanical thermostats in the 1994 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy, and Sovereign spa models This retrofit remedy was introduced to solve the ...read more
-
OBSOLETE-Use part 77118 IQ2020 heater relay board for the 2009 5 to 2012 5 Hot Spring, Tiger River, and Limelight spa models For earlier Hot Spring, Tiger River and Limelight spas use part 77119 This is the Invensys heater relay board for the IQ 2020 ...read more
-
Sku: 31027
Switch, GFCI 20Amp 115V
OBSOLETE 20amp GFI for all Hot Spring & Tiger River spa models that utilized a GFCI mounted in the control box prior to the power cord mounted GFCI This is a common hardware store item -
Obsolete: use 77119 This obsolete IQ2020 Heater Relay Circuit Board is used on the 2001-2009 5 IQ2020 Control Box It's upgraded design provides a more efficient method of connecting the heater's power cord to this board reducing fatigue on the three ...read more
-
Obsolete, use 77119
-
Sku: 34929
Terminal Block 5 Pos.
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Terminal Block 5 Pos -
Sku: 75089
Thermostat Control, Hot Spot
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Electronic Control Thermostat, Thermistor and Temperature Dial-This electronic thermostat mounts in the ...read more
Showing 1–30 of 36 results