I would like to express how excellent this company is. I inherited a house with a 2007 Hotspring Aria hot tub. The spa hasn’t been operated in years and when I turned it on, it ran for about 10 minutes and died. I mean dead died. I knew absolutely nothing about hot tubs but with the excellent diagnosis videos, installation videos and superior phone support, I was able to replace the main control board, heater relay board, heater, circulation pump, the ozonator and all associated tubing. This took 4 1/2 hours over two days (I had to watch videos) but the spa runs like new! I had one question regarding the jumper voltage 18 or 12. I spoke with a technician and he was able to answer my question as well as helping me double check the voltages for the components on the relay board. I am handy with electronics and electricity and am comfortable working with 230 volts. Shipping was fast and as expected. I highly recommend BackYardPlus.On 06/28/2024 by F. R. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing 1–30 of 59 results
-
BACK IN STOCK! Newest IQ 2020 Spa Control System for most Hot Spring and Limelight spas beginning the 3rd quarter of 2012, and all Hot Spring and Limelight spa models beginning in 2013 What's included: Main control board "motherboard" and the heater ...read more$640.88 Select Options
-
This is the IQ 2020 spa control system also called "Hawk control box" made for most Hot Spot brand spas built in the 3rd quarter of 2012, and all Hot Spot models beginning in 2013 It houses the electronics and circuitry that interface the spa controls with ...read more$459.68 Select Options
-
This IQ 2020 control box is the spa control system for 2006 to 3rd quarter 2012 Hot Spot models and Solana spas beginning in 2006 Please be aware that the control panel that is compatible with this control box unit ("Cedric" system with Invensys circuitry) ...read more
-
This Gecko IN YJ 2 control box replaces the now obsolete 76091 control box used on 2003-2005 Hot Spot SX and TX wired for 115v, Solana RX 2003- 2005 and Hot Spot Spring 2010-2011 and Hot Spot Dash 2010-2012 hot tubs This entire retrofit will need the ...read more
-
This Gecko IN YJ 3 control box used on 2022 Hot Spot Relay and Rhythm This control box is for a 2 pump system wired for 230 volts This entire retrofit will include: Specifications: 2 Pump 230v 60Hz
-
Sku: 77726-BYP
Control Box, 1999-2005 Hot Spot and Solana Retrofit, Gecko IN.YJ 3 Series, 115/230 Volt, 60HZ, After-Market
The Gecko IN YJ 3 control box is part of the retrofit that replaces the discontinued S-Class control system This retrofit is for the following Hot Spot and Solana models: 1 Pump Systems Hot Spot 1999-2000 SE (Y) 1999-2002 RE (Z), RLX (Z/ZQ), SLX ...read more -
Sku: 77726-BUNDLE
Gecko IN.YJ 3 Series Complete System, 1999-2005 Hot Spot and Solana After-Market Retrofit
The Gecko IN YJ 3 Series complete system is the retrofit used on: Hot Spot 1999-2000 SE (Y); 1999-2002 RE (Z), RLX (Z/ZQ), SLX (Y/YQ); 2001-2002 SLXtra (W/WQ); 2003-2005 Sorrento (SOR/SORS), Tobago (TOB), Trinidad (TRI); 2010-2012 Dash (DAS) Solana ...read more -
This is the IQ 2020 spa control system PUG control box retrofit for international spas only (50hz) Hot Spring, Tiger River and Limelight export models Notes from manufacturer: When retrofitting Control Box or Control Panel, must also order appropriate ...read more
-
Sku: 77271-OPENBOX
Control Box, Pug, Retrofit, 60HZ (Open Box)
Replacement for the discontinued IQ 2020 (73223) that was used on all 2001-2009 5 Hot Spring, Tiger River and Limelight spas This control box is also the retrofit upgrade replacement for the discontinued IQ 2000 (71382) that was used on all 1997 Hot Spring ...read moreOpen Box Warning! Read warning -
Factory replacement control box with heater for the now obsolete 71584 control box used on the 1999-2002 Hot Spot RE, RLX, SE, SLX, and 2001-2002 SLXtra and the Solana 2000-2002 X (triangle shaped), 2003-2005 Solana RX, SX, and TX spa models Note ...read more
-
Sku: 72469
Control Box, Hot Spot
Factory replacement control box for the 2003-2005 Hot Spot Mallorca, Sorrento, Trinidad & Tobago, and the 2002-2005 Caldera Oasis I & Oasis II spa models -
Sku: 37335
Control Box, Hot Spot
Factory original control box found on the 1998 Hot Spot RE, RLX, SE, SLX, and SLXtra spa models It comes complete with the circuit board, GFCI, electronic t-stat, high limit thermistor, relays, and heavy-duty power cord -
This control thermostat was mounted in the control box directly behind the temperature dial on all Hot Spring models from 1989-1993 It was mounted on the under the top-side control panel on all Tiger River models from 1992-1994
-
Sku: 36021
Program Jumper
This program jumpers can be found on the motherboard of all IQ 2000 and IQ 2020 Control Boxes Also used on the Interlock Timer Board (70821) -
This sensor fitting is installed through the side spa shell at the base of the hot tub near the suction and drain fittings on Hot Spot models beginning in 2020 Its purpose is to provide a watertight seal around the 72493 temperature control thermistor bulb
-
Sku: 76112
Thermistor Sensor Fitting, Hot Spot
This sensor fitting is installed through the side of the filter housing in all 1998-2005 Hot Spot brand spas Its purpose is to provide a watertight seal around the 71578 thermistor bulb -
Sku: 36021-x4-BYP
Program Jumpers (Qty of 4)
(Quantity of 4) Pack of program jumpers used on the motherboards of all IQ 2000 and 2001-2009 5 IQ 2020 Control Boxes Also used on the Interlock Timer Board ( 70821 ) -
Sku: 33249
Thermostat, Control, Hot Spot
This Control Thermostat is the replacement for the 1993-1994 Hot Spot Z (round spa) spa model -
Sku: 37727
Thermosensor Fitting, Solana
This thermo-sensor fitting is used to waterproof the temperature sensor (thermistor) that is located in the filter compartment of all Solana TX, RX and SX models -
Sku: 34934
Fuse 2 Amp 250V
2 amp 250v fuse for the 1995-1998 Hot Spot RE, RLX, SE, and SLX spa models as well as the 2009 forward IQ 2020 control boxes -
Sku: 72361
Fuse, Freshwater III, 1/2A 250V FAST-BLO
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Small size fuse used in the Freshwater 3 Ozonator unit -
Sku: 30118
Cordgrip, Thermostat
This cord grip fitting is what seals around the 30203 and the 75077 control thermostats copper wire May require the 30690 adapter (not included) -
Used on the 1995-1997 Hot Spot spas this fitting provided a flange for the cartridge-style heater element to seal against and a "dry-well" for the thermistor probe to slide into
-
Sku: 37089
Fuse SLOBLO 1/2A 250V 5x20in
This is a replacement fuse for the circulation pump line on IQ 2020 control boxes on all Hotsprings, Tiger River, and Limelight spas The fuse holder is mounted in the back of the control box near the circulation pump terminals on the circuit board A ...read more -
Kit includes both 6 3A and 8A fuse, 3pk each for Cool Zone
-
Sku: 34506
Fuseholder
Fuse holder houses the fuse for the older Freshwater II Ozonators and is also used to house the fuse for the circ pump circuit on IQ 2000 and IQ2020 control boxes -
Sku: 35196
Fuse, Freshwater II Ozonator
This is the fuse used to protect the Freshwater II Ozonator -
Sku: 71618
Fuse, 25Amp 300V Type SC-25
Slo-blo fuse used on the 71584, 73859, 72469, and 76840 control boxes for the pump and heater circuits -
Sku: 34500
Fuse 1.5A 230V Slo-Blo
One of two fuses used on the 70821 circuit board To test this fuse, remove it from the board and check the resistance from end to end If the fuse is good, the fuse should test closed with no resistance If it is bad, it should show an open circuit -
Sku: 302556
Fuse 2A 250V Slo-Blo
Replacement fuse found in the newest IQ 2020 control box on all 2012 5 Hot Spring and Limelight spas
Showing 1–30 of 59 results