Best place ever, always goodOn 05/31/2024 by M. D. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 17 results
-
Sku: 77726-BUNDLE
Gecko IN.YJ 3 Series Complete System, 1999-2005 Hot Spot and Solana After-Market Retrofit
The Gecko IN YJ 3 Series complete system is the retrofit used on: Hot Spot 1999-2000 SE (Y); 1999-2002 RE (Z), RLX (Z/ZQ), SLX (Y/YQ); 2001-2002 SLXtra (W/WQ); 2003-2005 Sorrento (SOR/SORS), Tobago (TOB), Trinidad (TRI); 2010-2012 Dash (DAS) Solana ...read more -
Heater connection wire kit, 8" long, 10 gauge wire, qty of 2 Connects from Hot Spot heater to board of S-Class series control box
-
Factory replacement control box with heater for the now obsolete 71584 control box used on the 1999-2002 Hot Spot RE, RLX, SE, SLX, and 2001-2002 SLXtra and the Solana 2000-2002 X (triangle shaped), 2003-2005 Solana RX, SX, and TX spa models Note ...read more
-
This jumper is used to bypass the pressure switch on the 2002-forward IQ 2020 spa control system The PDR Titanium Replacement Heater has its own automatic cut-off in the event of a low flow condition thus negating the need for a pressure switch After ...read more
-
This Hot Spot heater electronic pressure switch is a safety device that will shut down the heater if a "low water flow" condition occurs It is used on Hot Spot models (except Sprint & Dash models) and Solana spa models Some symptoms of failure include ...read more
-
Sku: 1306501
Power jumper, 2 pin, 15mm, Hawk
This 2 pin jumper is used in the Cedric Control box (73859) as well as the Hawk control box (76840) for Hot Spot tubs -
Sku: 39192-X2-BYP
Power Jumper, Heater Relay Board, 2-pin
2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board -
Sku: 39193-X2-BYP
Power Jumpers, Heater Relay Board, 3-Pin (pkg of 2)
Package of two 3-pin metal jumpers is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style Heater Relay Board there are two of these 3 pin jumpers The jumpers are inserted flat on the top edge of the heater ...read more -
Sku: 39193
Power Jumper, Heater Relay Board, 3-Pin
The 3-pin metal jumper is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style heater relay board, there are two of these 3 pin jumpers The jumpers are inserted flat just above the gray terminal block numbered ...read more -
This Hot Spot heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
This after-market heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
Sku: 39192
Power Jumper, Heater Relay Board, 2-Pin
This 2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board The 3-pin jumper is also used depending on the spa model and whether it's wired 120v or 240v -
This pressure switch is a safety device that screws into the heater and connects to the control box's main circuit board The main circuit board (motherboard) will shut down the heater if a "low water flow" condition occurs as monitored by this pressure ...read more
-
Sku: 71377
Power Jumper, Terminal Block, IQ 2000
Jumpers used on the IQ 2000 control box terminal block for 120-volt operation or converting from 120 volt to 230 volt -
Sku: 71377-x3-BYP
Power Jumper, Terminal Block, IQ 2000
Kit of three jumpers used for configuring the voltage on the IQ2000 control system used from 1997 to 2000 on Hot Springs and Tiger River spa The configuration of the jumpers allows for conversion between 120 volt and 230 volt operation -
Sku: 33232
Pressure Switch, Hot Spot
This replacement pressure switch is for the 1993-1994 Hot Spot Z (round spa) as well as the 1998 Hot Spot RE, RLX, SE, and SLX Notes: When the pressure switch senses proper water flow, the switch remains closed However, if the pressure switch senses a ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Heater control box assembly, Tiger River Manora and Sumatran
Showing all 17 results