CONTROL BOXES

These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.

Electrical: Pressure Switch, Surge Protector, Terminal Block, Timer Circuit Board

Showing all 16 results

  • Pressure Switch Bypass Jumper, IQ 2020 Spa Control System
    This jumper is used to bypass the pressure switch on the 2002-forward IQ 2020 spa control system The PDR Titanium Replacement Heater has its own automatic cut-off in the event of a low flow condition thus negating the need for a pressure switch After ...read more
    $29.30
    Add to cart
  • Electronic Pressure Switch, Solana and Hot Spot Heater
    This Hot Spot heater electronic pressure switch is a safety device that will shut down the heater if a "low water flow" condition occurs It is used on Hot Spot models (except Sprint & Dash models) and Solana spa models   Some symptoms of failure include ...read more
    $60.35
    Add to cart
  • Pressure Switch, After-Market, Solana and Hot Spot Heater
    This after-market heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
    $27.36 View OEM
    Add to cart
  • Pressure Switch, Solana and Hot Spot Heater
    This Hot Spot heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
    $47.26 View Generic
    Add to cart
  • Surge Protector, Relay Connection
    Relay surge protector (aka transient suppressor) used on all 1990-1993 Hot Spring spa models and on the third quarter 1995 220volt Hot Spring models This is one of two types of surge protectors used in the Hot Spring brand The second style is 31458
    $11.50
    Add to cart
  • Pressure Switch, Hot Spot Sprint and Dash
    This pressure switch is a safety device that screws into the heater and connects to the control box's main circuit board The main circuit board (motherboard) will shut down the heater if a "low water flow" condition occurs as monitored by this pressure ...read more
    $27.60
    Add to cart
  • Pressure Switch, Hot Spot
    This replacement pressure switch is for the 1993-1994 Hot Spot Z (round spa) as well as the 1998 Hot Spot RE, RLX, SE, and SLX Notes: When the pressure switch senses proper water flow, the switch remains closed However, if the pressure switch senses a ...read more
    $53.82
    Add to cart
  • Timer Chip, 10 Min. Delay, Hot Spot
    The 10 Minute Timer Delay is designed to cause the "heating mode" in the 1993-1994 Hot Spot Z model (round spa) to wait for 10 minutes before engaging This device is utilized whenever the spa is powered up or when the spa's jet pump is turned off This gives ...read more
    $124.61
    Add to cart
  • Terminal Block, Hot Spot
    Terminal Block, Hot Spot, 1998   This Terminal Block is part of the 1998 Hot Spot Control Box Assembly (Complete Control Box Part 37335) It is found on the 1998 Hot Spot RE, RLX, SE, SLX, and SLXtra spa models
    $10.96
    Add to cart
  • Circulation Timer Board, Hot Spring, Tiger River
    The circulation pump timer board operates the "Summer Timer" mode in the 120 volt 1996 Hot Spring and Tiger River spas
    $112.20
    Add to cart
  • Surge Protector, Hot Spring, Hot Spot, Tiger River
    Obsolete by factory: no replacement Surge protector used in '94-'96 Hot Spring, '92-'94 Tiger River on the GFCI and in all '93-'97 Hot Spot spa models This is one of two types of surge protectors used in Hot Spring, Tiger River, & Hot Spot brands The ...read more
  • Interlock Timer Circuit Board
    Sku: 70821

    Interlock Timer Circuit Board

    This item is obsolete and replaced by:
    77271
    Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This PWA: Interlock Timer Circuit Board is the factory replacement for all 1994-1996 Hot Spring Classic, ...read more
  • Terminal Block 5 Pos.
    Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Terminal Block 5 Pos
  • Terminal Block, IQ 2000
    Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This terminal block is used for the incoming power in the IQ2000 control boxes used in Hot Springs and ...read more
  • Timer Board, 10 Min., Hot Spring
    Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This factory replacement jet pump timer board is for the 1991-1993 Hot Spring Classic, Grandee, ...read more
  • Terminal Block 8Pos 30A 300V
    Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Terminal Block 8Pos 30A 300V

Showing all 16 results