On 03/05/2024 by C. W. (verified customer)
Showing 61–90 of 105 results
-
Sku: 71986
Rj-12 Phone Connector, 25 Pack
25 Pack of the connectors that go on the end of the cable for the replacement aux panels for spas made beginning in 1998 -
Sku: 302556
Fuse 2A 250V Slo-Blo
Replacement fuse found in the newest IQ 2020 control box on all 2012 5 Hot Spring and Limelight spas -
Sku: 74413
Pillow Light Control Board
This board is used inside the IQ2020 control box from 2008 to 2009 5 Hot Springs spas to enable the lighting behind the pillows to be connected to the control box -
Sku: 70106
Thermowell, Hot Spring
This thermowell (dry well) houses the spa high limit capillary (probe) and the thermostat probe in the 1989-1990 Hot Spring Sovereign (a k a Indoor/Outdoor model), 1989-1990 Prodigy (aka Home Spa) and the 1989-1994 Jetsetter -
Sku: 32452
Harness, Pcb 4T 115V 5Kw
Wiring harness for a 10-minute timer circuit board used on all models 1991 to 1993 Hot Springs spas The timer board is part number 71346 and is currently unavailable -
Sku: 74140
15A-ATC/ATO Blade Fuse
15A-ATC/ATO blase fuse -
Sku: 74139
IA-3AG Fast Acting Fuse
IA-3AG fast-acting fuse -
Sku: 71853
Cable Retrofit Kit, Hot Spring
The cable retrofit kit is used on the third through fourth quarter 1996 Hot Spring Landmark and Summit spas when upgrading from the original discontinued control box with the newer 1997 IQ2000 control box This cable is only necessary if the flow switch is ...read more -
The circulation pump timer board operates the "Summer Timer" mode in the 120 volt 1996 Hot Spring and Tiger River spas
-
This rotating jet switch is located in the control box of some pre-1989 Hot Spring spa models It is activated by rotating the "Jets" dial on the exterior control panel
-
Sku: 32425
Switch, Toggle
This toggle switch was used on the 1991-1993 Grandee to turn off the "Timed Jets" feature an also used on the 115 volt Hot Spring and Tiger River spa models to activate the "Summer Mode" (aka Summer Timer) -
Sku: 30171
Heater Receptacle, 220v. Hot Spring
Used on the 1989 Hot Spring 220volt models The Grandee, Highlife, Sovereign IH and Classic FH -
Sku: 30167
Receptacle, 15A 125V Snap In
Used on the pre-1989 Hot Spring Classic, Indoor/Outdoor, Personal spa, Jetsetter, and Home Spa as the circulation pumps power supply as well the power supply to the heater Also used on the 1989 Grandee before the introduction of the square style receptacle -
Sku: 34481
Screw Receptacle
Screw Receptacle -
(Package of 5) The standoffs are plastic pins used to mount this circuit board onto the inside of the control box This keeps the backside of circuit boards from touching the metal case of the control box in all 1990-1993 Hot Spring spa models
-
Sku: 1316901
Control Box Plug, 1.093 Diameter
Plastic plug used to seal the largest unused round holes in the bottom of the IQ 2020 Control Box on all 2012 5 Hot Spring and Limelight spas These plugs keep critters from crawling into the control box -
Thermowell housing for the t-stat temperature probe to insert into This thermowell aka "drywell" keeps the copper t-stat probe away from the chlorinated water so it doesn't dissolve
-
Sku: 71811
Interlock Switch Bypass Kit
Interlock switch bypass kit -
This IQ 2020 spa control system is the replacement for the discontinued IQ 2020 control box (73223 Invensys circuitry) that was used on all 2001-2009 5 Hot Spring, Tiger River, and Limelight spas This control box is also the retrofit upgrade replacement for ...read more
-
Sku: 39204
Thermistor, High-Limit, Hot Spring, Tiger River, Limelight
This item is obsolete and replaced by:
79005This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 39205
Thermistor, Control Thermostat, Hot Spring, Tiger River and Limelight
This item is obsolete and replaced by:
79006This control thermostat thermistor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 38415
Thermistor, Control Thermostat, Hot Spring and Tiger River
This item is obsolete and replaced by:
78970This control thermostat thermistor sensor detects the spa waters temperature and relays that information back to the system It simply screws into the No Fault Heater Housing (hand tight only) and plugs into the outside of the spa's control box If your ...read more -
Sku: 38416
Thermistor, High-Limit, Hot Spring and Tiger River
This item is obsolete and replaced by:
78969This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 30209
Hi-Limit, Heater, 150 degree, Hot Spring
OBSOLETE: This Heater Hi-Limit (red "heater reset" button) is designed to kill power to the heater if the core temperature exceeds 150 deg The probe of this high-limit is inserted into the end of the heater element and surrounded with plumbers putty to ...read more -
Sku: 34321
Relay, DPST 30A 12Volt DC
This 30amp double pole/single throw 12volt coil relay was used for various purposes Used for a light, heater, interlock, low-speed jet pump, high-speed jet pump, and circulation pump relay in all 1994-1996 Hot Spring, all 1995-1998 Hot Spot, and all ...read more -
Sku: 10490
Dimmer Switch, Hot Spring
This 115volt dimmer switch is used in all 1990-1996 Hot Spring spas This is one of two types of dimmers used in Hot Spring spa models The second choice is the 30189 used in all pre-1990 Hot Springs Note: Do not use a floodlight larger than 100 watts ...read more -
OBSOLETE This is the replacement thermistor for all 1994 Hot Spring spa models and 1995-1998 Hot Spot RE, RLX, SE & SLX spa models This Control Thermostat Thermistor communicates the actual water temperature to the controller to shut off the heater ...read more
-
Obsolete by factory: no replacement Surge protector used in '94-'96 Hot Spring, '92-'94 Tiger River on the GFCI and in all '93-'97 Hot Spot spa models This is one of two types of surge protectors used in Hot Spring, Tiger River, & Hot Spot brands The ...read more
-
Sku: 72742
I2C 4-Port Comm Hub
This 4 port adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug onto the motherboard If your adding on a IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light etc , you'll need this adapter The 8 ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This PWA: Interlock Timer Circuit Board is the factory replacement for all 1994-1996 Hot Spring Classic, ...read more
Showing 61–90 of 105 results