Great service, great price. When it appeared the shipment might be a day or so late, there was great communication. We will definitely be back as a customer.On 07/03/2024 by G. L. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 22 results
-
This jumper is used to bypass the pressure switch on the 2002-forward IQ 2020 spa control system The PDR Titanium Replacement Heater has its own automatic cut-off in the event of a low flow condition thus negating the need for a pressure switch After ...read more
-
Replaces the obsolete 39525 and obsolete 39204 Newly designed and includes o-ring This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 ...read more
-
Sku: 79006
Thermistor, Control Thermostat, Watkins No Fault Heater, Hot Spring, Tiger River and Limelight
Replaces the obsolete 39530 and obsolete 39205 Newly designed and includes o-ring This control thermistor is a safety device that measures the water temperature of your spa and communicates that temperature reading to the Motherboard It simply screws ...read more -
Replaces 38415 Newly designed and includes o-ring This control thermostat thermistor sensor detects the spa waters temperature and relays that information back to the system It simply screws into the No Fault Heater Housing (hand tight only) and plugs ...read more
-
Replaces 38416 Newly designed and includes o-ring This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws ...read more
-
Sku: 30208
Hi-Limit, Spa, 120 Degree, Hot Spring
This Spa Hi-Limit thermostat (aka spa reset or tub reset) is a safety device designed to prevent damage to the spa that would occur if the spa overheated The probe of this high-limit resides in a "drywell" along with the thermostat probe The spa high-limit ...read more -
Sku: 36044
Plug, Hole, 0.50
This plug is used to fill openings found on the back of the IQ2000 and IQ2020 Control box that can be used to allow wiring to enter the control box These plugs cover the openings that are not in use to help prevent dust, dirt, and insects from entering the ...read more -
Sku: 36043
Control Box Plug, for 0.875 Hole
Black plastic plug used on the IQ 2000 and IQ 2020 Control Boxes to seal off an unused port helping to prevent bugs, dirt and debris from making a home inside the control box -
This Heater High-Limit (red heater reset button) is the replacement for the Hot Spring Classic (Model D)
-
Sku: 32425
Switch, Toggle
This toggle switch was used on the 1991-1993 Grandee to turn off the "Timed Jets" feature an also used on the 115 volt Hot Spring and Tiger River spa models to activate the "Summer Mode" (aka Summer Timer) -
Sku: 71811
Interlock Switch Bypass Kit
Interlock switch bypass kit -
This IQ 2020 spa control system is the replacement for the discontinued IQ 2020 control box (73223 Invensys circuitry) that was used on all 2001-2009 5 Hot Spring, Tiger River, and Limelight spas This control box is also the retrofit upgrade replacement for ...read more
-
Sku: 39204
Thermistor, High-Limit, Hot Spring, Tiger River, Limelight
This item is obsolete and replaced by:
79005This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 39205
Thermistor, Control Thermostat, Hot Spring, Tiger River and Limelight
This item is obsolete and replaced by:
79006This control thermostat thermistor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 38415
Thermistor, Control Thermostat, Hot Spring and Tiger River
This item is obsolete and replaced by:
78970This control thermostat thermistor sensor detects the spa waters temperature and relays that information back to the system It simply screws into the No Fault Heater Housing (hand tight only) and plugs into the outside of the spa's control box If your ...read more -
Sku: 38416
Thermistor, High-Limit, Hot Spring and Tiger River
This item is obsolete and replaced by:
78969This high-limit thermistor sensor is a safety device designed to communicate with the system to shut down the heater if the water temperature exiting your heater exceeds 118 degrees F It simply screws into the No-Fault Heater Housing (hand tight only) and ...read more -
Sku: 30209
Hi-Limit, Heater, 150 degree, Hot Spring
OBSOLETE: This Heater Hi-Limit (red "heater reset" button) is designed to kill power to the heater if the core temperature exceeds 150 deg The probe of this high-limit is inserted into the end of the heater element and surrounded with plumbers putty to ...read more -
OBSOLETE This is the replacement thermistor for all 1994 Hot Spring spa models and 1995-1998 Hot Spot RE, RLX, SE & SLX spa models This Control Thermostat Thermistor communicates the actual water temperature to the controller to shut off the heater ...read more
-
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This obsolete electronic high-limit is the replacement for the 1995-1996 Hot Spring Grandee, Highlife, ...read more
-
Sku: 85005-BYP
Control Box Components, Hot Spring
OBSOLETE This rebuild kit includes all the original components found inside the control box of a 1990-1993 Hot Spring Classic, Sovereign, Indoor-Outdoor, Prodigy, Home Spa and Jetsetter For those of us who want to start with a clean slate, everything ...read more -
Sku: 71485
IQ 2000 Control Box, Hot Spring and Tiger River
This item is obsolete and replaced by:
77271OBSOLETE-Factory replacement suggestion item 77271 Factory replacement IQ 2000 control box (main circuit board enclosed in a protective casing) for the 1998-2000 Hot Spring Grandee, Landmark, Classic, Sovereign, Prodigy and Jetsetter spa models It's also ...read more -
OBSOLETE-Factory replacement suggestion item 77271 with Control Head 73225
Showing all 22 results