Great service, great price. When it appeared the shipment might be a day or so late, there was great communication. We will definitely be back as a customer.On 07/03/2024 by G. L. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing 1–30 of 49 results
-
Sku: 77119
IQ 2020 Heater Relay Board
This IQ2020 Heater Relay Circuit Board is the newest revision for the 2001-2009 5 IQ2020 Control Box It's upgraded design provides a more efficient method of connecting the heater's power cord to this board, therefore, reducing fatigue on the two "beefed up" ...read more -
This is the IQ 2020 heater relay board compatible with the Eagle IQ 2020 spa control system for all forward Hot Spring and Limelight models as well as Tiger River spa retrofits Reference: 1302801-1
-
Sku: 77726-BUNDLE
Gecko IN.YJ 3 Series Complete System, 1999-2005 Hot Spot and Solana After-Market Retrofit
The Gecko IN YJ 3 Series complete system is the retrofit used on: Hot Spot 1999-2000 SE (Y); 1999-2002 RE (Z), RLX (Z/ZQ), SLX (Y/YQ); 2001-2002 SLXtra (W/WQ); 2003-2005 Sorrento (SOR/SORS), Tobago (TOB), Trinidad (TRI); 2010-2012 Dash (DAS) Solana ...read more -
This IQ 2020 heater relay board replaces the now obsolete 76071 (Orca with Invensys Circuitry) This IQ 2020 heater relay board is for the 2009 5 to 2012 5 Hot Spring, Tiger River and Limelight spa models using the Orca (Invensys control box system) For ...read more
-
Sku: 30-01395-K
Thermistor Adapters, After-Market
The after-market thermistor adapters work to allow the after-market thermistors to connect to the outside of the control box instead of connecting directly to the motherboard of the control box -
This control thermostat was mounted in the control box directly behind the temperature dial on all Hot Spring models from 1989-1993 It was mounted on the under the top-side control panel on all Tiger River models from 1992-1994
-
Sku: 36021
Program Jumper
This program jumpers can be found on the motherboard of all IQ 2000 and IQ 2020 Control Boxes Also used on the Interlock Timer Board (70821) -
This sensor fitting is installed through the side spa shell at the base of the hot tub near the suction and drain fittings on Hot Spot models beginning in 2020 Its purpose is to provide a watertight seal around the 72493 temperature control thermistor bulb
-
Sku: 76112
Thermistor Sensor Fitting, Hot Spot
This sensor fitting is installed through the side of the filter housing in all 1998-2005 Hot Spot brand spas Its purpose is to provide a watertight seal around the 71578 thermistor bulb -
Sku: 36021-x4-BYP
Program Jumpers (Qty of 4)
(Quantity of 4) Pack of program jumpers used on the motherboards of all IQ 2000 and 2001-2009 5 IQ 2020 Control Boxes Also used on the Interlock Timer Board ( 70821 ) -
Sku: 33249
Thermostat, Control, Hot Spot
This Control Thermostat is the replacement for the 1993-1994 Hot Spot Z (round spa) spa model -
Sku: 37727
Thermosensor Fitting, Solana
This thermo-sensor fitting is used to waterproof the temperature sensor (thermistor) that is located in the filter compartment of all Solana TX, RX and SX models -
Mounts in the control box on all Hot Spring models prior to 1997 that used a square receptacle The one-speed circulation pump (Silentflo 5000) plugs into this receptacle regardless of the voltage of your spa model All Hot Spring spa circulating pumps are ...read more
-
Used on the 1995-1997 Hot Spot spas this fitting provided a flange for the cartridge-style heater element to seal against and a "dry-well" for the thermistor probe to slide into
-
Sku: 10408
Receptacle, Jet Pump, Hot Spring
This jet pump receptacle mounts into the control box to provide an outlet to plug in the jet pump's power cord on the 1990-1996 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy & Sovereign spa models -
Sku: 74150
I2 C/RS485, 5-Port Comm Hub, IQ 2020
This 5 port I2C/RS485 adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug into the motherboard If you're adding on an IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light, etc , you'll need this ...read more -
Sku: 34894
Jet Pump Receptacle
Jet Pump Receptacle (for two-speed pumps) used on Hot Spot spas prior to 1998 -
Cable connector assembly for Khyber
-
Sku: 33920
Timer Chip, 10 Min. Delay, Hot Spot
The 10 Minute Timer Delay is designed to cause the "heating mode" in the 1993-1994 Hot Spot Z model (round spa) to wait for 10 minutes before engaging This device is utilized whenever the spa is powered up or when the spa's jet pump is turned off This gives ...read more -
Sku: 71986
Rj-12 Phone Connector, 25 Pack
25 Pack of the connectors that go on the end of the cable for the replacement aux panels for spas made beginning in 1998 -
Sku: 74413
Pillow Light Control Board
This board is used inside the IQ2020 control box from 2008 to 2009 5 Hot Springs spas to enable the lighting behind the pillows to be connected to the control box -
Sku: 32452
Harness, Pcb 4T 115V 5Kw
Wiring harness for a 10-minute timer circuit board used on all models 1991 to 1993 Hot Springs spas The timer board is part number 71346 and is currently unavailable -
This 220volt heater receptacle is located in the 1995-1996, 220volt Tiger River Manora & Tondi control box It provides a place to plug in the heater Over the years, this item can fatigue and require replacement For the 120volt receptacle see part 35114
-
The circulation pump timer board operates the "Summer Timer" mode in the 120 volt 1996 Hot Spring and Tiger River spas
-
Sku: 71280
Thermowell, Hot Spot Square
Thermowell houses the temperature sensor for Hot Spot Square -
Sku: 70899
Thermowell Assembly
Thermowell houses the thermistor probe on a 1995-1997 Hot Spot spa models -
Sku: 35112
Freshwater Ozone Receptacle, Tiger River
The female plug is installed in the control box and is used to plug in the Freshwater Ozonator on the Pre-1997 Tiger River Manora, Tondi & Khyber spa models -
Sku: 30170
Receptacle, Single – 20A 115V
Single receptacle, 20A 115V -
Sku: 34481
Screw Receptacle
Screw Receptacle -
Thermowell housing for the t-stat temperature probe to insert into This thermowell aka "drywell" keeps the copper t-stat probe away from the chlorinated water so it doesn't dissolve