Good company. Honest. ThanksOn 06/03/2024 by D. S. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 23 results
-
Sku: 74723
Relay, IQ 2000 Control Box
This 30amp 18volt DC coil relay is used in the 1997 and 1998-2000 Hot Spring & Tiger River IQ 2000 Control Box There are two of these relays located in the upper left corner of the IQ 2000 control box One is the heater relay and one is the heater ...read more -
This is the replacement flow switch for the 1995-1996 Hot Spring Classic, Sovereign, Prodigy and Jetsetter spa models It is also the replacement for the 1995-1996 Tiger River Manora and Tondi spa models This low voltage flow switch monitors the flow of ...read more
-
Sku: 70297
Relay, DPST 110VDC Coil
This relay (or contactor) is also known as the Interlock Relay & Heater Relay is a 110VDC coil 30amp and was used on the 1990-1993 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy & Sovereign spa models Also used on the 1992-1994 Tiger River ...read more -
This is the replacement flow switch for the 1995-1996 Hot Spring 220 only Classic, Sovereign, Grandee, Highlife, Landmark and Summit spa models It is also the replacement for the 1995-1995 Tiger River Khyber spa model This low voltage switch is located in ...read more
-
Sku: 33263
Flow Switch, Tiger River
This is the replacement flow switch for the 1992-1994 Tiger River Khyber, Manora and Tondi spa models -
Sku: 70298
Relay, DPDT DC Coil
This double-pole/double-throw DC coil relay was used on the 1991-1993 Hot Spring Classic, Sovereign, Prodigy, Jetsetter, Highlife and Grandee spa models Used also on the 1992-1994 Tiger River Khyber spa model -
Sku: 34831
Flow Switch, Hot Spot
This is the replacement for the 1995-1997 Hot Spot Z model (round spa) and the Y model (rectangle spa) -
Sku: 34488
Relay, Power 30Amp 110Volt DC
This 30 amp 110-volt double-pole/single throw relay was used on the 1993-1994 Hot Spot Z (round) model and the 1994 Tiger River Khyber as a jet pump relay Check your serial number in the parts finder above to be sure this part is for your spa -
Sku: 74150
I2 C/RS485, 5-Port Comm Hub, IQ 2020
This 5 port I2C/RS485 adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug into the motherboard If you're adding on an IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light, etc , you'll need this ...read more -
Sku: 33920
Timer Chip, 10 Min. Delay, Hot Spot
The 10 Minute Timer Delay is designed to cause the "heating mode" in the 1993-1994 Hot Spot Z model (round spa) to wait for 10 minutes before engaging This device is utilized whenever the spa is powered up or when the spa's jet pump is turned off This gives ...read more -
Sku: 33231
Relay, 20Amp SPST 110Volt DC
This 20amp single pole/single throw 110 volt DC relay was used 1993-1994 Hot Spot Z (round) model spa -
Sku: 74413
Pillow Light Control Board
This board is used inside the IQ2020 control box from 2008 to 2009 5 Hot Springs spas to enable the lighting behind the pillows to be connected to the control box -
Sku: 70838
Capacitor Relay Upgrade Kit-Hot Spot Z
This upgrade kit is needed for the Hot Spot Z (round) model prior to Z-240133 (2nd quarter 1994) and comes with instructions for replacement from Z-330001 (3rd qtr 1993) to Z-240133 (2nd qtr 1994) Note: Factory photo shows that this includes a resistor ...read more -
The circulation pump timer board operates the "Summer Timer" mode in the 120 volt 1996 Hot Spring and Tiger River spas
-
This double-pole/double-throw 110 volt DC relay was used on the 1993-1994 Hot Spot Z (round) model spa
-
Sku: 71129
Test Leads, Pomona 5682 Black
TEST LEADS, POMONA 5682 BLACK -
Sku: 71131
Test Leads, Pomona 5682 Red
Test lead, Pomona 5682, Red -
Sku: 33767
Relay, 30A 12VDC
Relay, 30A 12VDC, #PRD-7DG2-12 -
Sku: 34321
Relay, DPST 30A 12Volt DC
This 30amp double pole/single throw 12volt coil relay was used for various purposes Used for a light, heater, interlock, low-speed jet pump, high-speed jet pump, and circulation pump relay in all 1994-1996 Hot Spring, all 1995-1998 Hot Spot, and all ...read more -
Sku: 72742
I2C 4-Port Comm Hub
This 4 port adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug onto the motherboard If your adding on a IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light etc , you'll need this adapter The 8 ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This PWA: Interlock Timer Circuit Board is the factory replacement for all 1994-1996 Hot Spring Classic, ...read more
-
Sku: 71346
Timer Board, 10 Min., Hot Spring
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This factory replacement jet pump timer board is for the 1991-1993 Hot Spring Classic, Grandee, ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This controller circuit board is found on the backside of all pre-1995 Tiger River Khyber, Manora & ...read more
Showing all 23 results