I would like to express how excellent this company is. I inherited a house with a 2007 Hotspring Aria hot tub. The spa hasn’t been operated in years and when I turned it on, it ran for about 10 minutes and died. I mean dead died. I knew absolutely nothing about hot tubs but with the excellent diagnosis videos, installation videos and superior phone support, I was able to replace the main control board, heater relay board, heater, circulation pump, the ozonator and all associated tubing. This took 4 1/2 hours over two days (I had to watch videos) but the spa runs like new! I had one question regarding the jumper voltage 18 or 12. I spoke with a technician and he was able to answer my question as well as helping me double check the voltages for the components on the relay board. I am handy with electronics and electricity and am comfortable working with 230 volts. Shipping was fast and as expected. I highly recommend BackYardPlus.On 06/28/2024 by F. R. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing all 27 results
-
This OEM replacement IQ 2020 control board (motherboard) is for all IQ 2020 Control Boxes (77271) found on all 2001-2009 5 Hot Spring, Tiger River and Limelight spa models It is used on domestic 60hz model spas only
-
This OEM replacement IQ 2020 control board is for the Orca Box (76082) which has the Invensys circuitry, 115/220 VAC, used on 2009 Phase 2 through 3rd Quarter 2012 Hot Spring, Tiger River, and Limelight If your circuitry is marked with a blue label that says ...read more
-
Sku: 77726-BUNDLE
Gecko IN.YJ 3 Series Complete System, 1999-2005 Hot Spot and Solana After-Market Retrofit
The Gecko IN YJ 3 Series complete system is the retrofit used on: Hot Spot 1999-2000 SE (Y); 1999-2002 RE (Z), RLX (Z/ZQ), SLX (Y/YQ); 2001-2002 SLXtra (W/WQ); 2003-2005 Sorrento (SOR/SORS), Tobago (TOB), Trinidad (TRI); 2010-2012 Dash (DAS) Solana ...read more -
Sku: 303550
Harness, LED Light
This LED light harness is used with item 303307 multicolored light and is apart of the retrofit replacement parts that include: 78448 Control Box 72093 Control Panel 77358 Heater 78451 Bracket 303307 LED Multi-Color Lightcross compatible with older ...read more -
Sku: 303307
LED Light, Multicolor, Hot Spot and Solana
This multicolor LED light is used with 78448 control box and is apart of the retrofit replacements parts listed below: 78448 Control Box 72093 Control Panel 77358 Heater 78451 Bracket 303307 LED Multi-Color Lightcross compatible with older control ...read more -
Grounding bar for the Hot Spot heater (after-market Gecko S-Class) 5 Position, 14-6 AWG This grounding bar is attached to the heater on Hot Spot and Solana brand spas and allows the pump and other accessories to have a secondary ground tied into the ...read more
-
Sku: 1306501
Power jumper, 2 pin, 15mm, Hawk
This 2 pin jumper is used in the Cedric Control box (73859) as well as the Hawk control box (76840) for Hot Spot tubs -
Sku: 39192-X2-BYP
Power Jumper, Heater Relay Board, 2-pin
2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board -
Sku: 39193-X2-BYP
Power Jumpers, Heater Relay Board, 3-Pin (pkg of 2)
Package of two 3-pin metal jumpers is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style Heater Relay Board there are two of these 3 pin jumpers The jumpers are inserted flat on the top edge of the heater ...read more -
Sku: 39193
Power Jumper, Heater Relay Board, 3-Pin
The 3-pin metal jumper is one of two different jumpers that are used on the original 73355 Heater Relay Board On the new style heater relay board, there are two of these 3 pin jumpers The jumpers are inserted flat just above the gray terminal block numbered ...read more -
Sku: 39192
Power Jumper, Heater Relay Board, 2-Pin
This 2-pin metal jumper is one of two different jumpers that are used on all years of the IQ 2020 Heater Relay Board The 3-pin jumper is also used depending on the spa model and whether it's wired 120v or 240v -
Sku: 10489
Bridge Wave Rectifier
This rectifier was used on the 1990-1993 Hot Spring Classic, Sovereign, Prodigy, Jetsetter, Highlife and Grandee, 1994 Tiger River Khyber and the 1993-1994 Hot Spot Z model -
Sku: 71377
Power Jumper, Terminal Block, IQ 2000
Jumpers used on the IQ 2000 control box terminal block for 120-volt operation or converting from 120 volt to 230 volt -
Sku: 71377-x3-BYP
Power Jumper, Terminal Block, IQ 2000
Kit of three jumpers used for configuring the voltage on the IQ2000 control system used from 1997 to 2000 on Hot Springs and Tiger River spa The configuration of the jumpers allows for conversion between 120 volt and 230 volt operation -
Sku: 74150
I2 C/RS485, 5-Port Comm Hub, IQ 2020
This 5 port I2C/RS485 adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug into the motherboard If you're adding on an IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light, etc , you'll need this ...read more -
This PWA Control Panel Interface board is only found on the 1995-1996 Tiger River Khyber, Manora and Tondi spa models It is located inside the control box
-
Sku: 33920
Timer Chip, 10 Min. Delay, Hot Spot
The 10 Minute Timer Delay is designed to cause the "heating mode" in the 1993-1994 Hot Spot Z model (round spa) to wait for 10 minutes before engaging This device is utilized whenever the spa is powered up or when the spa's jet pump is turned off This gives ...read more -
Sku: 74413
Pillow Light Control Board
This board is used inside the IQ2020 control box from 2008 to 2009 5 Hot Springs spas to enable the lighting behind the pillows to be connected to the control box -
Sku: 71974
PWA Main Circuit Board, Hot Spot
This PWA Main Circuit Board is the factory replacement for the 1998 Hot Spot RE, RLX (round), SE and SLX (square) models The picture may differ slightly from your circuit board due to revisions but this board will be a "Plug 'N Play" replacement -
The circulation pump timer board operates the "Summer Timer" mode in the 120 volt 1996 Hot Spring and Tiger River spas
-
Sku: 72742
I2C 4-Port Comm Hub
This 4 port adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug onto the motherboard If your adding on a IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light etc , you'll need this adapter The 8 ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This PWA: Interlock Timer Circuit Board is the factory replacement for all 1994-1996 Hot Spring Classic, ...read more
-
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This main circuit board is for the 1992-1994 Tiger River Khyber wired 220volt
-
Sku: 71346
Timer Board, 10 Min., Hot Spring
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This factory replacement jet pump timer board is for the 1991-1993 Hot Spring Classic, Grandee, ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This controller circuit board is found on the backside of all pre-1995 Tiger River Khyber, Manora & ...read more
-
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This 115 volt main circuit board is for the 1992-1994 Tiger River Manora and Tondi models This 115volt ...read more
-
Recently released for sale by the factory, this OEM replacement motherboard is for the Orca Box (Invensys Circuitry) (76082), 115/220 VAC, used on 2009 Phase 2 through 3rd Quarter 2012 Hot Spring, Tiger River, and Limelight
Showing all 27 results