Great service, great price. When it appeared the shipment might be a day or so late, there was great communication. We will definitely be back as a customer.On 07/03/2024 by G. L. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing 1–30 of 31 results
-
Sku: 77119
IQ 2020 Heater Relay Board
This IQ2020 Heater Relay Circuit Board is the newest revision for the 2001-2009 5 IQ2020 Control Box It's upgraded design provides a more efficient method of connecting the heater's power cord to this board, therefore, reducing fatigue on the two "beefed up" ...read more -
This is the IQ 2020 heater relay board compatible with the Eagle IQ 2020 spa control system for all forward Hot Spring and Limelight models as well as Tiger River spa retrofits Reference: 1302801-1
-
This IQ 2020 heater relay board replaces the now obsolete 76071 (Orca with Invensys Circuitry) This IQ 2020 heater relay board is for the 2009 5 to 2012 5 Hot Spring, Tiger River and Limelight spa models using the Orca (Invensys control box system) For ...read more
-
This control thermostat was mounted in the control box directly behind the temperature dial on all Hot Spring models from 1989-1993 It was mounted on the under the top-side control panel on all Tiger River models from 1992-1994
-
Sku: 33249
Thermostat, Control, Hot Spot
This Control Thermostat is the replacement for the 1993-1994 Hot Spot Z (round spa) spa model -
Sku: 33229
Air Switch (Latching), Hot Spot
This latching air switch was used for two different purposes on Hot Spot spa models In 1993-1994 is was used as a jet activation switch In 1995-1998 it was used as a light activation switch It is connected with a clear vinyl tube to the air button located ...read more -
Sku: 74150
I2 C/RS485, 5-Port Comm Hub, IQ 2020
This 5 port I2C/RS485 adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug into the motherboard If you're adding on an IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light, etc , you'll need this ...read more -
Sku: 75076
15 amp Mini Breaker, Hot Spot
This 15amp Mini Breaker is located on the control box on all 1993-1998 Hot Spot spa models This reset button is identified by the number 15 located on the round portion of the reset button -
Sku: 75076-Generic
16 amp Mini Breaker, Hot Spot (After Market)
GENERIC (This does not come from Hot Spring factory and does not have a one year warranty) This generic replacement 15amp Mini Breaker is used to replace the original mini breaker located on the control box on all 1993-1998 Hot Spot spa models The reset ...read more -
The jet switch is located in the control box of all 1995-1998 Hot Spot spa models It is connected with a clear vinyl tube to the air button located on the bartop of the Hot Spot models Once the air button is depressed a puff of air activates this switch In ...read more
-
Cable connector assembly for Khyber
-
Sku: 33920
Timer Chip, 10 Min. Delay, Hot Spot
The 10 Minute Timer Delay is designed to cause the "heating mode" in the 1993-1994 Hot Spot Z model (round spa) to wait for 10 minutes before engaging This device is utilized whenever the spa is powered up or when the spa's jet pump is turned off This gives ...read more -
Sku: 74413
Pillow Light Control Board
This board is used inside the IQ2020 control box from 2008 to 2009 5 Hot Springs spas to enable the lighting behind the pillows to be connected to the control box -
Sku: 70838
Capacitor Relay Upgrade Kit-Hot Spot Z
This upgrade kit is needed for the Hot Spot Z (round) model prior to Z-240133 (2nd quarter 1994) and comes with instructions for replacement from Z-330001 (3rd qtr 1993) to Z-240133 (2nd qtr 1994) Note: Factory photo shows that this includes a resistor ...read more -
The circulation pump timer board operates the "Summer Timer" mode in the 120 volt 1996 Hot Spring and Tiger River spas
-
Sku: 71129
Test Leads, Pomona 5682 Black
TEST LEADS, POMONA 5682 BLACK -
Sku: 71131
Test Leads, Pomona 5682 Red
Test lead, Pomona 5682, Red -
Sku: 72742
I2C 4-Port Comm Hub
This 4 port adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug onto the motherboard If your adding on a IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light etc , you'll need this adapter The 8 ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This PWA: Interlock Timer Circuit Board is the factory replacement for all 1994-1996 Hot Spring Classic, ...read more
-
OBSOLETE This Electronic Control Thermostat (thermistor included) replaces the mechanical thermostats in the 1994 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy, and Sovereign spa models This retrofit remedy was introduced to solve the ...read more
-
OBSOLETE-Use part 77118 IQ2020 heater relay board for the 2009 5 to 2012 5 Hot Spring, Tiger River, and Limelight spa models For earlier Hot Spring, Tiger River and Limelight spas use part 77119 This is the Invensys heater relay board for the IQ 2020 ...read more
-
Obsolete: use 77119 This obsolete IQ2020 Heater Relay Circuit Board is used on the 2001-2009 5 IQ2020 Control Box It's upgraded design provides a more efficient method of connecting the heater's power cord to this board reducing fatigue on the three ...read more
-
Obsolete, use 77119
-
Sku: 75089
Thermostat Control, Hot Spot
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com Electronic Control Thermostat, Thermistor and Temperature Dial-This electronic thermostat mounts in the ...read more -
Sku: 71346
Timer Board, 10 Min., Hot Spring
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This factory replacement jet pump timer board is for the 1991-1993 Hot Spring Classic, Grandee, ...read more -
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This electronic thermostat is the replacement for the 1995-1996 Hot Spring Grandee, Highlife, Landmark, ...read more
-
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This controller circuit board is found on the backside of all pre-1995 Tiger River Khyber, Manora & ...read more
-
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This Control Thermostat is a bulb and capillary type thermostat coated with Teflon due to the direct ...read more
-
Obsolete: No factory suggested replacement available at this time Please contact our technicians for advice (805) 541-9000 or wizard@backyardplus com This Control Thermostat is a bulb and capillary type thermostat coated with Teflon due to the direct ...read more
Showing 1–30 of 31 results