I would like to express how excellent this company is. I inherited a house with a 2007 Hotspring Aria hot tub. The spa hasn’t been operated in years and when I turned it on, it ran for about 10 minutes and died. I mean dead died. I knew absolutely nothing about hot tubs but with the excellent diagnosis videos, installation videos and superior phone support, I was able to replace the main control board, heater relay board, heater, circulation pump, the ozonator and all associated tubing. This took 4 1/2 hours over two days (I had to watch videos) but the spa runs like new! I had one question regarding the jumper voltage 18 or 12. I spoke with a technician and he was able to answer my question as well as helping me double check the voltages for the components on the relay board. I am handy with electronics and electricity and am comfortable working with 230 volts. Shipping was fast and as expected. I highly recommend BackYardPlus.On 06/28/2024 by F. R. (verified customer)
These control boxes and their circuit boards do on occasion just grow tired as any outdoor computer could. No worries, we have just the right complete factory replacements as well as the internal parts all from the makers of Hot Spring, Tiger River, Solana, Limelight, and Hot Spot Spas.
Showing 1–30 of 54 results
-
BACK IN STOCK! Newest IQ 2020 Spa Control System for most Hot Spring and Limelight spas beginning the 3rd quarter of 2012, and all Hot Spring and Limelight spa models beginning in 2013 What's included: Main control board "motherboard" and the heater ...read more$640.88 Select Options
-
This is the IQ 2020 spa control system also called "Hawk control box" made for most Hot Spot brand spas built in the 3rd quarter of 2012, and all Hot Spot models beginning in 2013 It houses the electronics and circuitry that interface the spa controls with ...read more$459.68 Select Options
-
This IQ 2020 control box is the spa control system for 2006 to 3rd quarter 2012 Hot Spot models and Solana spas beginning in 2006 Please be aware that the control panel that is compatible with this control box unit ("Cedric" system with Invensys circuitry) ...read more
-
This Gecko IN YJ 2 control box replaces the now obsolete 76091 control box used on 2003-2005 Hot Spot SX and TX wired for 115v, Solana RX 2003- 2005 and Hot Spot Spring 2010-2011 and Hot Spot Dash 2010-2012 hot tubs This entire retrofit will need the ...read more
-
This Gecko IN YJ 3 control box used on 2022 Hot Spot Relay and Rhythm This control box is for a 2 pump system wired for 230 volts This entire retrofit will include: Specifications: 2 Pump 230v 60Hz
-
Sku: 77726-BYP
Control Box, 1999-2005 Hot Spot and Solana Retrofit, Gecko IN.YJ 3 Series, 115/230 Volt, 60HZ, After-Market
The Gecko IN YJ 3 control box is part of the retrofit that replaces the discontinued S-Class control system This retrofit is for the following Hot Spot and Solana models: 1 Pump Systems Hot Spot 1999-2000 SE (Y) 1999-2002 RE (Z), RLX (Z/ZQ), SLX ...read more -
Sku: 77726-BUNDLE
Gecko IN.YJ 3 Series Complete System, 1999-2005 Hot Spot and Solana After-Market Retrofit
The Gecko IN YJ 3 Series complete system is the retrofit used on: Hot Spot 1999-2000 SE (Y); 1999-2002 RE (Z), RLX (Z/ZQ), SLX (Y/YQ); 2001-2002 SLXtra (W/WQ); 2003-2005 Sorrento (SOR/SORS), Tobago (TOB), Trinidad (TRI); 2010-2012 Dash (DAS) Solana ...read more -
This is the IQ 2020 spa control system PUG control box retrofit for international spas only (50hz) Hot Spring, Tiger River and Limelight export models Notes from manufacturer: When retrofitting Control Box or Control Panel, must also order appropriate ...read more
-
Sku: 77271-OPENBOX
Control Box, Pug, Retrofit, 60HZ (Open Box)
Replacement for the discontinued IQ 2020 (73223) that was used on all 2001-2009 5 Hot Spring, Tiger River and Limelight spas This control box is also the retrofit upgrade replacement for the discontinued IQ 2000 (71382) that was used on all 1997 Hot Spring ...read moreOpen Box Warning! Read warning -
Factory replacement control box with heater for the now obsolete 71584 control box used on the 1999-2002 Hot Spot RE, RLX, SE, SLX, and 2001-2002 SLXtra and the Solana 2000-2002 X (triangle shaped), 2003-2005 Solana RX, SX, and TX spa models Note ...read more
-
Sku: 72469
Control Box, Hot Spot
Factory replacement control box for the 2003-2005 Hot Spot Mallorca, Sorrento, Trinidad & Tobago, and the 2002-2005 Caldera Oasis I & Oasis II spa models -
Sku: 37335
Control Box, Hot Spot
Factory original control box found on the 1998 Hot Spot RE, RLX, SE, SLX, and SLXtra spa models It comes complete with the circuit board, GFCI, electronic t-stat, high limit thermistor, relays, and heavy-duty power cord -
This jumper is used to bypass the pressure switch on the 2002-forward IQ 2020 spa control system The PDR Titanium Replacement Heater has its own automatic cut-off in the event of a low flow condition thus negating the need for a pressure switch After ...read more
-
This Hot Spot heater electronic pressure switch is a safety device that will shut down the heater if a "low water flow" condition occurs It is used on Hot Spot models (except Sprint & Dash models) and Solana spa models Some symptoms of failure include ...read more
-
This after-market heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
This Hot Spot heater pressure switch (looks like a radiator thermostat) is a safety device that screws into the heater that will shut down the heater if a "low water flow" condition occurs It is used on all 1999-2005 Hot Spot spa models as well as all ...read more
-
Sku: 35628
Surge Protector, Relay Connection
Relay surge protector (aka transient suppressor) used on all 1990-1993 Hot Spring spa models and on the third quarter 1995 220volt Hot Spring models This is one of two types of surge protectors used in the Hot Spring brand The second style is 31458 -
This pressure switch is a safety device that screws into the heater and connects to the control box's main circuit board The main circuit board (motherboard) will shut down the heater if a "low water flow" condition occurs as monitored by this pressure ...read more
-
Mounts in the control box on all Hot Spring models prior to 1997 that used a square receptacle The one-speed circulation pump (Silentflo 5000) plugs into this receptacle regardless of the voltage of your spa model All Hot Spring spa circulating pumps are ...read more
-
Sku: 33232
Pressure Switch, Hot Spot
This replacement pressure switch is for the 1993-1994 Hot Spot Z (round spa) as well as the 1998 Hot Spot RE, RLX, SE, and SLX Notes: When the pressure switch senses proper water flow, the switch remains closed However, if the pressure switch senses a ...read more -
Sku: 10408
Receptacle, Jet Pump, Hot Spring
This jet pump receptacle mounts into the control box to provide an outlet to plug in the jet pump's power cord on the 1990-1996 Hot Spring Classic, Grandee, Highlife, Jetsetter, Prodigy & Sovereign spa models -
Sku: 74150
I2 C/RS485, 5-Port Comm Hub, IQ 2020
This 5 port I2C/RS485 adapter is used to "expand" the IQ2020 Controller to allow other accessories to plug into the motherboard If you're adding on an IQ 2020® Navigator RF Remote, Music System, Luminescence Multi-Colored LED Light, etc , you'll need this ...read more -
Sku: 75076
15 amp Mini Breaker, Hot Spot
This 15amp Mini Breaker is located on the control box on all 1993-1998 Hot Spot spa models This reset button is identified by the number 15 located on the round portion of the reset button -
Sku: 75076-Generic
16 amp Mini Breaker, Hot Spot (After Market)
GENERIC (This does not come from Hot Spring factory and does not have a one year warranty) This generic replacement 15amp Mini Breaker is used to replace the original mini breaker located on the control box on all 1993-1998 Hot Spot spa models The reset ...read more -
Sku: 34894
Jet Pump Receptacle
Jet Pump Receptacle (for two-speed pumps) used on Hot Spot spas prior to 1998 -
Sku: 33920
Timer Chip, 10 Min. Delay, Hot Spot
The 10 Minute Timer Delay is designed to cause the "heating mode" in the 1993-1994 Hot Spot Z model (round spa) to wait for 10 minutes before engaging This device is utilized whenever the spa is powered up or when the spa's jet pump is turned off This gives ...read more -
Sku: 74413
Pillow Light Control Board
This board is used inside the IQ2020 control box from 2008 to 2009 5 Hot Springs spas to enable the lighting behind the pillows to be connected to the control box -
This 220volt heater receptacle is located in the 1995-1996, 220volt Tiger River Manora & Tondi control box It provides a place to plug in the heater Over the years, this item can fatigue and require replacement For the 120volt receptacle see part 35114
-
The circulation pump timer board operates the "Summer Timer" mode in the 120 volt 1996 Hot Spring and Tiger River spas
-
Sku: 35112
Freshwater Ozone Receptacle, Tiger River
The female plug is installed in the control box and is used to plug in the Freshwater Ozonator on the Pre-1997 Tiger River Manora, Tondi & Khyber spa models